Monitoring and Troubleshooting Access Manager
8-58
Access Manager 2000 User Manual
Test Time Remaining: This line shows time in hours, minutes,
and seconds (hh:mm:ss) that the CSU will be generating the test
signal. When the timer reaches 00:00:00, the test generation will
be disabled and error counting will stop.
Looped: Indicates which near-end loop is in effect (LLB, PLB,
ELB, or RLB). Although different loopbacks may be used
concurrently, only the relevant loop to the CSU test will be
displayed.
Errors: This shows the number of errors which the NCC (CCC)
or TAC has detected in the incoming test signal.
Lower Screen Section: Shows the monitored condition of the
received signal. This screen only shows what type of error is
occurring; it does not indicate what is causing the error. A green
N under the current column indicates that no errors are
occurring for the listed condition. A red Y indicates a testing or
error condition.
10. Press to return to the Select Test Activity screen.
11. The list of CSU circuit elements which are accumulating test results
are displayed on the CSU Tests in Progress screen.
Each CSU circuit element is listed with the test it is performing.
Access Manager keeps track of up to 13 separate tests.
Test entries are deleted in three ways: