Configuring the T1 Network
5-64
Access Manager 2000 User Manual
This option must be set to YES and the Installed and
Operational option must also be set to YES to enable Access
Manager to configure the selected CSU circuit elements.
In the following figures, the options following Enable Remote
Configuration are downloaded to the CSU circuit element when
is pressed. View the appropriate figure (for your equipment) from
the list below:
If this option is set to NO, any changes made are only saved in the
database but are not
downloaded to the CSU circuit element. Remote
configuration refers to the fact that these options are downloaded from the
Access Manager database.
Note:
You should set the Enable Remote Configuration
option to YES only during the time that the actual remote
configuration is being performed. This is to avoid performing a
remote configuration (if this option is set to YES) each time you
edit a circuit element just to change the data to be collected.
This option sets the bit error rate (BER) threshold on the network side to a
rate from 10
-4
to 10
-9
, with a default value of 10
-6
.
A value of ZERO disables the BER alarm function.
The approximate length of time for automatic alarm to reset may vary
according to which BER threshold you select, as shown in the following
two tables.
■ Table 5-8, “Older CSU Circuit Elements BER Alarm Rest Times”
■ Table 5-9, “Newer CSU Circuit Elements BER Alarm Reset Times”
Enable Remote
Configuration
F5
BER Threshold