Verilink Access Manager 2000 (896-502037-001) Product Manua Manual de usuario Pagina 212

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 400
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 211
Configuring the T1 Network
5-88
Access Manager 2000 User Manual
This option functions like Signal to EQP on LOS option
described below, except the trigger condition is LOF. See warning in that
section. The default is YES.
If this option is set to YES, then whatever signal is received from the
network is sent to the equipment.
If this option is set to NO, then AIS is sent to the equipment until the LOS
alarm clears. The default is YES (signal).
CAUTION
Setting this option to NO causes an out-of-service condition during
LOS from the network, starting when the condition is detected and
lasting as long as the condition persists plus from 0 seconds to 255
seconds (depending on the user-selected alarm delay time). The
default is 10 seconds.
This option is functionally similar to the EQP Receive Jitter
Buffer = 40 Bits option, except that the buffer in this option is for
the incoming signal from the network. The default setting is YES.
When set to YES (the default), the ESF Data Link idle code is ALL-
ONEs. When this option is set to NO, the Data Link idle code is Flags.
Set this option to YES (default) to allow the CSU to automatically
perform a self-test each time it is powered up.
Set this option to YES (default setting) if you want the CSU to respond to
loopback commands sent to it either on the ESF Data Link or directly
from Access Manager.
Signal to EQP on
NET LOF
Signal to EQP on
NET LOS
!
NET RCV Jitte
BUF = 40 Bits
Data Link Idle
Code (Idle code) =
Flags
Power-up Near End
Self Test
Loopback Enable