T1 Network Monitoring Overview
Access Manager 2000 User Manual
5
-
7
Operationally, each far-end CSU is managed as if it were a node as
well as a circuit element. The node Query Path field must have
NONE as its chosen option.
In summary, the far-end CSU is both defined as a node and
configured as an element.
5.
Menu used: Main/Configuration/Element/Edit
Select the configuration parameters for each far-end CSU you’ll use,
and use to attempt to download the configuration. A message
will come up saying that you need to build a circuit first. Although
your actual download was “unsuccessful”, you did succeed in
building a spot for the configuration in the database.
6.
Near-end node
Access Manager 2000
C
S
U
Far-end node #1
C
S
U
T1 Facility Data Link
C
S
U
Far-end node #3
C
S
U
C
S
U
C
S
U
Far-end node #2
Build the database for the far-end CSU parameters.
Near-end node
Access Manager 2000
C
S
U
Far-end nodes #1 & #2
C
S
U
T1 Facility Data Link
C
S
U
Far-end node #3
C
S
U
C
S
U
C
S
U
F5
Configure a circuit between the CSUs.