Verilink HDM 2182 User ManualOctober 1999P/N 880-502925-001-GPRIEXTMANAGEMENTHDM2182ABSYSNETLOCALPORTSNMP
HDM 2182 DS3 DSU Overview1-2 Verilink HDM 2182 User ManualFeaturesFeatures of the HDM 2182 include the following:Front Panel Management PortsThe HDM
HDM 2182 DS3 DSU OverviewVerilink HDM 2182 User Manual 1-3Inband Management ChannelSpecialized support is provided for the inband management channel
HDM 2182 DS3 DSU Overview1-4 Verilink HDM 2182 User Manual•The HDM can be managed with a graphical user interface (GUI) using Verilink’s Node Manager
HDM 2182 DS3 DSU OverviewVerilink HDM 2182 User Manual 1-5HDM 2182 SpecificationsTable 1-1 Network SpecificationsTable 1-2 Data Port SpecificationsTa
HDM 2182 DS3 DSU Overview1-6 Verilink HDM 2182 User ManualRegulatory RequirementsThis product complies with the following regulatory specifications a
HDM 2182 DS3 DSU OverviewVerilink HDM 2182 User Manual 1-7•When an HDM 2182 is used in a Dual-line shelf without an NCM 2000, the HDM 2182 must be mo
HDM 2182 DS3 DSU Overview1-8 Verilink HDM 2182 User ManualFigure 1-6 Terminal Block One on the MLS—Chassis Ground Connected to Signal GroundFigure 1-
Verilink HDM 2182 User Manual2-1Chapter2HDM 2182 Quick Set-UpThis chapter provides step-by-step procedures for setting up your HDM 2182 module. This
HDM 2182 Quick Set-Up2-2Verilink HDM 2182 User ManualNOTE:The node controller module (NCM 2000) is usually installed in slot 1 of shelf 1. However, fo
HDM 2182 Quick Set-UpVerilink HDM 2182 User Manual 2-3Figure 2-2 NCM Main Menu From the NCM Craft interface Main Menu (Figure 2-2), select the HDM app
iiVerilink HDM 2182 User ManualCopyright NoticeCopyright 1999 Verilink Corporation. All rights reserved.This document does not create any express or
HDM 2182 Quick Set-Up2-4 Verilink HDM 2182 User ManualFigure 2-3 Configuration Menu Network PortThe DS3 network port is usually configured before the
HDM 2182 Quick Set-UpVerilink HDM 2182 User Manual 2-54. Exit this menu and return to the Configuration Menu.HSSI Port Set-up1. Type “H” to display th
HDM 2182 Quick Set-Up2-6 Verilink HDM 2182 User ManualEnter an identifying character string (no more than 18 characters) to specify the Circuit ID. “P
Verilink HDM 2182 User Manual 3-1Chapter3Standalone HDM 2182 ManagementThis chapter describes the Craft interface menu options for a standalone HDM 21
Standalone HDM 2182 Management3-2 Verilink HDM 2182 User ManualFigure 3-1 ASCII Screen: Main Menu via HDM 2182 Local PortTable 3-1 HDM 2182 Craft Inte
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-3Although Table 3-1 above presents application management options in the order as they a
Standalone HDM 2182 Management3-4 Verilink HDM 2182 User ManualFigure 3-2 Node Administration Menu --- ADMINISTRATION MENU --- --- ADMINIST
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-5Table 3-2 HDM 2182 Node Administration OptionsCommand DescriptionA Node Address—Use thi
Standalone HDM 2182 Management3-6 Verilink HDM 2182 User ManualM Management trap IP address1—This is an IP address to which alarm messages will be sen
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-7Port Configuration MenuOnce you have established and set the HDM 2182’s IP addresses an
Verilink HDM 2182 User Manualiii • If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you
Standalone HDM 2182 Management3-8 Verilink HDM 2182 User ManualFigure 3-4 DS3 Network Port Configuration Submenu Table 3-4 DS3 Port Configuration Subm
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-9C Clock Source—Displays the current status and provides a prompt asking if you want to
Standalone HDM 2182 Management3-10 Verilink HDM 2182 User ManualHSSI Port ConfigurationFrom the Port Configuration Menu, select H or I for the HSSI
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-11Table 3-5 HSSI Port Configuration Submenu ChoicesPort Diagnostics MenuWhen the node ad
Standalone HDM 2182 Management3-12 Verilink HDM 2182 User ManualFigure 3-6 Port Diagnostics Menu Table 3-6 Port Diagnostics Menu CommandsHDM > dHD
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-13Port Loopback Diagnostics MenuBy returning transmitted signals to their source for com
Standalone HDM 2182 Management3-14 Verilink HDM 2182 User ManualTable 3-7 Port Loopback Diagnostics Menu CommandsTransmit Alarms Diagnostics AlarmsTo
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-15NOTE:Only one FEAC alarm can be sent at a time.Figure 3-8 Transmit Alarms Diagnostics
Standalone HDM 2182 Management3-16 Verilink HDM 2182 User ManualTable 3-8 Transmit Alarms Diagnostics Menu OptionsCommand DescriptionY Transmit Yellow
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-17DS3 Performance Monitoring MenuPressing P from the Main Menu displays the DS3 Performa
ivVerilink HDM 2182 User ManualDeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität
Standalone HDM 2182 Management3-18 Verilink HDM 2182 User ManualTable 3-9 Performance Monitoring Menu Command OptionsDS3 NE Performance Monitoring Men
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-19To display the data for any of the parameters listed in the DS3 NE Performance Monitor
Standalone HDM 2182 Management3-20 Verilink HDM 2182 User ManualPerformance DataDisplaysFor example, to see the 24 hr Near End Line Code Violation Per
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-21Figure 3-12 DS3 Layer Local FE Performance Monitoring Submenu DS3 Layer Performance Al
Standalone HDM 2182 Management3-22 Verilink HDM 2182 User ManualFigure 3-14 DS3 Layer Performance Alert Thresholds Submenu DS3 Layer Performance Alert
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-23Figure 3-16 Qtr Hr Alerts Crossing Threshold (Local FE) (DS3 Layer Performance Alert T
Standalone HDM 2182 Management3-24 Verilink HDM 2182 User ManualTable 3-11 Restore Manufacturing Default Config Menu OptionsCommand DescriptionA TX D
Standalone HDM 2182 ManagementVerilink HDM 2182 User Manual 3-25Alarm MonitoringTo see real-time, continuous alarm notifications, from the Main Menu,
Standalone HDM 2182 Management3-26 Verilink HDM 2182 User Manual
Verilink HDM 2182 User Manual 4-1Chapter4HDM 2182 Management: Using NCM 2000 ASCII Access SettingsTo access an HDM 2182 on the node from an ASCII term
Verilink HDM 2182 User Manualv • This product should be operated only from the type of power source indicated on the marking label and manual. If you
HDM 2182 Management: Using NCM 20004-2 Verilink HDM 2182 User ManualNCM Controller Menu (Main Menu)The NCM Controller Menu (Main Menu) displays the co
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-3Figure 4-1 NCM Controller Menu (Showing HDM 2182 at Shelf 1, Slot 1)When accessing
HDM 2182 Management: Using NCM 20004-4 Verilink HDM 2182 User ManualTable 4-1 HDM 2182 NCM Controller Menu Commands Shelf and Slot ParametersWhen acce
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-5Figure 4-2 Card Administration Menu via NCMTable 4-3 Card Administration Menu Comm
HDM 2182 Management: Using NCM 20004-6 Verilink HDM 2182 User ManualConfiguration MenuTyping the command C from the Main Menu displays the HDM Configu
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-7Figure 4-4 Port Configuration Menu (DS3)Table 4-5 HDM 2182 Port Configuration Menu
HDM 2182 Management: Using NCM 20004-8 Verilink HDM 2182 User ManualHSSI Port n Configuration MenusSelecting either H or I from the Configuration Menu
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-9Table 4-6 HSSI Port A Configuration Menu Commands Remote End SetupSelecting R fr
HDM 2182 Management: Using NCM 20004-10 Verilink HDM 2182 User Manualconnected to the far-end of a DS3 port before enabling the inband on this DS3 por
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-11Diagnostics MenuSelecting D from the NCM Controller Menu (Main Menu) displays the
viVerilink HDM 2182 User Manual
HDM 2182 Management: Using NCM 20004-12 Verilink HDM 2182 User ManualFigure 4-9 Loopbacks A and BDS3 Port Status ReportSelecting P from the Diagnostic
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-13Table 4-9 HDM 2180 Loopback Options Menu CommandsCommand DescriptionA Activate L
HDM 2182 Management: Using NCM 20004-14 Verilink HDM 2182 User ManualHDM Transmit Alarm OptionsSelecting T from the Diagnostics Menu displays the HDM
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-15Performance / Status MenuSelecting P from the Main Menu displays the Performance/
HDM 2182 Management: Using NCM 20004-16 Verilink HDM 2182 User Manual15 MinuteThreshold SelectorMenuSelecting M from the Performance Threshold Setting
HDM 2182 Management: Using NCM 2000Verilink HDM 2182 User Manual 4-17Table 4-13 HDM 2182 Performance Report Options Menu CommandsAlarm MenuSelecting A
HDM 2182 Management: Using NCM 20004-18 Verilink HDM 2182 User ManualFar End DS3 Port IdentificationSelecting F from the Main Menu displays the Far En
Verilink HDM 2182 User Manual 5-1Chapter5Standalone HDM 2182 SNMP Management NOTE:Before using SNMP, Telnet, FTP, or other TCP/IP protocol, you must s
Standalone HDM 2182 SNMP Management5-2 Verilink HDM 2182 User ManualEmbedded Network Management System Using SNMPThe SNMP port connects to an Ethernet
Standalone HDM 2182 SNMP ManagementVerilink HDM 2182 User Manual 5-3•HDM 2182 uses SNMPv1 community strings.•HDM 2182 provides filtering of SNMPv1 PDU
Table of ContentsVerilink HDM 2182 User Manual viiHDM 2182 DS3 DSU Overview ...
Standalone HDM 2182 SNMP Management5-4 Verilink HDM 2182 User Manual
Verilink HDM 2182 User Manual 6-1Chapter6TroubleshootingWhat Elicits an AlarmThe NCM 2000 module polls the HDM 2182 modules for alarms.If alarm report
Troubleshooting6-2 Verilink HDM 2182 User ManualAlarm ListingsOn any of the various listings of the alarms being received by the NCM for the HDM, the
TroubleshootingVerilink HDM 2182 User Manual 6-3What To Do About AlarmsSome alarms will clear after the user-configured timeout has expired. Other ala
Troubleshooting6-4 Verilink HDM 2182 User Manual•Alarm Indication Signal Second (AISS)—A second when the CSU receives an unframed all-ones Alarm Indic
TroubleshootingVerilink HDM 2182 User Manual 6-5second integration period upon detection of LOS or LOF before a yellow alarm is sent to the far-end eq
Troubleshooting6-6 Verilink HDM 2182 User ManualInterpreting Front Panel LEDsFigure 6-1 HDM 2182 Front Panel LED IndicatorsHDM 2182 provides tri-colo
TroubleshootingVerilink HDM 2182 User Manual 6-7LCV Line code violationsLES Line errored secondsLOFS Loss of frame secondLOSS Loss of signal secondLSE
Troubleshooting6-8 Verilink HDM 2182 User ManualFar-End AlarmsThe following far-end alarms are detected and reported:FEBE Far End Block ErrorFEAC DS3
IndexVerilink HDM 2182 User Manual Index-1Aadministration submenu 4-4AISS 6-4, 6-5AISS (Alarm Indication Signal Second) 6-4, 6-5alarm buffer 3-25ala
viii Verilink HDM 2182 User Manual HDM 2182 Management: Using NCM 2000 ... 4-
Index-2 Verilink HDM 2182 User ManualNCM Controller Menu 4-2near-end performance parameters 6-6node address 3-5node administration 3-3Node Manager 5
VERILINK CORPORATION127 JETPLEX CIRCLE, MADISON, ALABAMA 35758TEL: (800) 837-4546October 1999P/N 880-502925-001G
Verilink HDM 2182 User Manual 1-1Chapter1HDM 2182 DS3 DSU OverviewThis manual describes how to use the HDM 2182 DS3 DSU Craft Interface. As part of V