Verilink HDM 2182 User Manual 3-1
Chapter
3
Standalone HDM 2182 Management
This chapter describes the Craft interface menu options for a
standalone HDM 2182 (no NCM 2000 controller module used for
management). See Chapter 4 for HDM features when using an NCM
2000 for management.
Using the Local Port
To access the HDM 2182 from an ASCII terminal:
1. Connect your ASCII terminal to the front panel LOCAL port.
2. Set your terminal parameters to the following values:
19.2 kbps baud rate
8 data bits
no parity
one stop-bit
no flow-control
Be sure that
X-
ON
/
X-
OFF
flow control is disabled.
3. Type “craft” and press E
NTER
.
4. At the PA SSWORD:
PASSWORD:PASSWORD:
PASSWORD: prompt, enter “verilink” (in lower case)
and press E
NTER
.
The HDM 2182 Craft Interface Main Menu (Main Menu)
displays.
HDM 2182 Craft Interface, Main Menu
The Main Menu is the starting point for all management tasks
accessed directly through the HDM 2182 Craft interface. The menu
title displays information such as the name and shelf/slot position
of the HDM 2182 module, its firmware version, and date/time. The
menu, with an explanation of each option, follows.