Verilink Access Manager 2000 (896-502037-001) Product Manua Manual de usuario Pagina 146

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 400
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 145
Configuring the T1 Network
5-22
Access Manager 2000 User Manual
ComDesign: The node’s network management port connects to a
statistical multiplexer.
X.25 PAD: The node’s network management port connects to an
X.25 PAD (Packet Assembler Disassembler).
Table 5-5 Node configuration options for older equipment
This includes the for 551VST List 1, 551VST List 1/A, 551VST List 1/B, and 551VST ML List 1. These equipment types
use TABS Protocol and do not support alarm reporting
.
Table 5-6 Node Configuration Option for newer equipment
This includes the 551VST (ML) List 2, SIM, NC/E, ConnecT1 Plus, and AS2000. These equipment types use OSI
protocol. The X.25 PAD can only be used with AS2000 equipment.
Access Arrangement (Connection)
Option Direct Modem
None
(Facility Data Link
or
Daisy Chain) ComDesign
Baud Rate (Note 1) 1200 1200 1200 120
Query Path COM 1-16 Phone No. None Port Name
Enable Alarm Reporting No No No No
NOTE 1. Currently, a modem (Comline) configured for 2400 baud cannot initiate calls to a node configured for
1200 baud. Configure the node in Access Manage for 2400 baud, and allow the modem to automatically
downgrade to 1200 baud.
Access Arrangement
(Connection) Option Direct Modem
None
(Facility Data Link
or Daisy Chain)
ComDesign
or
X.25 PAD
Report alarms:
Baud Rate (Note 1) 9600 1200/2400 1200/9600 9600
Query Path COM 1-16 Phone No. None Port Name
Alarm Path COM 1-16 Phone No. None Access Manager Port
Name
Previous Node in Chain
(Note 2, 3
Node Name None None None
Enable Alarm Reporting Yes Yes No Yes
Do not report alarms:
Alarm Path None None None None
Vista de pagina 145
1 2 ... 141 142 143 144 145 146 147 148 149 150 151 ... 399 400

Comentarios a estos manuales

Sin comentarios