Analyzing Performance Data
7-18
Access Manager 2000 User Manual
8. All information in the database prior to and including the selected
date is sent to the report printer. The printer can be a file on a disk
drive, as defined in the Report Printer Definition screen.
9. See Appendix E "Archive File Formats" for an analysis of this
performance data log. This completes the printing of performance
data records (of the type selected).
To copy the reports to disk and delete the data:
1. Starting from the Main Menu, select Database Access.
2. From the Database Access (Performance Database Analysis)
screen, select Archive. The Archive (Performance Database:
Choose Archive Option) screen appears.
3. From this screen, select Archive (Copy Records to Disk
with Delete Option).
The Choose Register Set to be Archived screen now appears.
4. Select the register type whose performance data records you want to
archive. EQPT and Additional register types are not present
nor reported for 551VST type circuit elements. A Select Archive
Cutoff Date screen appears.
5. Enter the month, day, and year (four digits) of the date up to which
you wish to archive the performance data records. The default date
is the current date.
6. Press to accept the date displayed or enter a new date. Press
to cancel the request.
Copying reports to
disk and deleting
the data
F5
F2