Verilink DCSU 2911 User ManualSeptember 1999P/N 880-502647-001-C1PRIEXTMANAGEMENTDCSU291112SYS21LOCALNETCPE
DCSU 2911 Dual Channel Service Unit1-2Verilink DCSU 2911 User ManualDCSU 2911 Front ModuleFigure 1-2 shows the DCSU 2911 front panel.Figure 1-2 DCSU 2
DCSU 2911 Dual Channel Service UnitVerilink DCSU 2911 User Manual1-3Connector Interface ModulesRear connector modules or connecter interface modules (
DCSU 2911 Dual Channel Service Unit1-4Verilink DCSU 2911 User ManualFigure 1-5 CIM 29002 LP Quad RJ-48 E1 (120Ω) CAUTIONDo not use E1 CIM 29002 LP in
DCSU 2911 Dual Channel Service UnitVerilink DCSU 2911 User Manual1-5 SpecificationsThe following specifications apply to the DCSU 2911 module.Table 1-
DCSU 2911 Dual Channel Service Unit1-6Verilink DCSU 2911 User Manual
Verilink DCSU 2911 User Manual2-1Chapter2DCSU 2911 Quick Set-UpThis chapter provides step-by-step procedures for setting up your DCSU 2911 module. Th
DCSU 2911 Quick Set-Up2-2Verilink DCSU 2911 User ManualConnect to Craft PortConnect the modular (RJ-11) end of the Craft cable to the port labeled LOC
DCSU 2911 Quick Set-UpVerilink DCSU 2911 User Manual2-33. From the DCSU Main Menu, select the following:ACE Controller Menu>O) ACE Controller Admin
DCSU 2911 Quick Set-Up2-4Verilink DCSU 2911 User ManualPort ConfigurationFrom the Main Menu, select option C, “Configuration”, to start the configurat
DCSU 2911 Quick Set-UpVerilink DCSU 2911 User Manual2-54. Type “B1”, then ENTER, to display the prompt:Port 1 line build out:Port 1 line build out:Por
iiVerilink DCSU 2911 User ManualCopyright NoticeCopyright 1999 Verilink Corporation. All rights reserved.This document does not create any express o
DCSU 2911 Quick Set-Up2-6Verilink DCSU 2911 User Manual10. Type “T1”, then ENTER, to display the Configuration Menu (Timing Options):Figure 2-5 Config
DCSU 2911 Quick Set-UpVerilink DCSU 2911 User Manual2-7Enter the destination port (1-4 or 'A' for all):Enter the destination port (1-4 or &a
DCSU 2911 Quick Set-Up2-8Verilink DCSU 2911 User ManualType “3” to select the now configured Net Port 3 (Equipment Port 1). The prompt will display:En
Verilink DCSU 2911 User Manual3-1Chapter3DCSU T1 Craft InterfaceThis chapter describes how to configure, operate, and test the DCSU 2911 T1 parameters
DCSU T1 Craft Interface3-2Verilink DCSU 2911 User ManualIn the screen displayed•Slots containing DCSU modules display a U at the intersection of rows
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-32. The physical location of the module—a node map (slot/shelf display table) in which the appl
DCSU T1 Craft Interface3-4Verilink DCSU 2911 User ManualAdministration Menu—Direct AccessEnter O from the Main Menu to use the Administration Menu to
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-5Table 3-3Administration Menu ParametersCommand Description OptionsT Set Time: Use this option
DCSU T1 Craft Interface3-6Verilink DCSU 2911 User ManualConfiguration MenuEnter C on the Main Menu to display the Configuration Menu.Figure 3-3 DCSU 2
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-7Table 3-4 DCSU Configuration Menu Command KeysCommand Description OptionsInIn Service: This o
Verilink DCSU 2911 User Manualiii • If the telephone company alters its equipment in a manner that can affect the use of this device, it must give you
DCSU T1 Craft Interface3-8Verilink DCSU 2911 User ManualNDnNetwork Density: This option specifies the type of network density. Digital transmissions o
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-9Configuration Menu (FDL Options) SubmenuThe Configuration Menu (FDL Options) is obtained by en
DCSU T1 Craft Interface3-10Verilink DCSU 2911 User ManualConfiguration Menu (Timing Options) SubmenuDisplay the Configuration Menu (Timing Options) su
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-11Alternate Timing Options SubmenuIf the option, “Receive clock from shelf” has been selected
DCSU T1 Craft Interface3-12Verilink DCSU 2911 User ManualFigure 3-6DCSU 2911 Configuration Menu (Timing Options) The following additional timing para
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-13Table 3-8 Diagnostics Menu ParametersCommand Description OptionsLnLine Loopback (LLB): This
DCSU T1 Craft Interface3-14Verilink DCSU 2911 User ManualWhen finished configuring the network port diagnostics parameters, enter X to return to the M
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-15To access the Performance/Status Menu from the Main Menu, enter P.Figure 3-8 DCSU 2911 Perfor
DCSU T1 Craft Interface3-16Verilink DCSU 2911 User Manualend, the cyclic redundancy check is calculated again and compared with the value generated by
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-17Net Port Alarm Threshold Status SubmenuEnter T from the Performance/Status Menu to access the
ivVerilink DCSU 2911 User ManualDeutschVORSICHT!Explosionsgefahr bei unsachgemäßem Ersetzen der Batterie! Batterie gleichen Typs und gleicher Qualität
DCSU T1 Craft Interface3-18Verilink DCSU 2911 User ManualFigure 3-11 DCSU 2911 Net Port Alarm Threshold Status Menu Net Port Alarm MenuDisplay the Net
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-19C Configure Thresholds: To disable any or all alarm conditions, enter a threshold value of 0.
DCSU T1 Craft Interface3-20Verilink DCSU 2911 User ManualNet Port Alarm Threshold Configuration SubmenuTo display the Net Port Alarm Threshold Configu
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-21Following is a brief description of the configure threshold parameters:Table 3-11 Net Port A
DCSU T1 Craft Interface3-22Verilink DCSU 2911 User ManualDisplay AlarmBuffersTo display the alarm buffer, enter O in the Net Port Alarm Menu. The alar
DCSU T1 Craft InterfaceVerilink DCSU 2911 User Manual3-23NOTE: The Manufacturing Information window provides useful information on the Dual CSU module
DCSU T1 Craft Interface3-24Verilink DCSU 2911 User Manual
Verilink DCSU 2911 User Manual4-1Chapter4DCSU 2911 E1 Craft InterfaceThis chapter describes how to configure, operate, and test the DCSU 2911 E1 param
DCSU 2911 E1 Craft Interface4-2Verilink DCSU 2911 User ManualIn the screen displayed•Slots containing DCSU modules display a U at the intersection of
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-32. The physical location of the module—a node map (slot/shelf display table) in which the
Verilink DCSU 2911 User Manualv • This product should be operated only from the type of power source indicated on the marking label and manual. If you
DCSU 2911 E1 Craft Interface4-4Verilink DCSU 2911 User ManualAdministration MenuEnter O from the Main Menu to use the Administration Menu to modify an
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-5Table 4-3Node Administration Parameters Command Description OptionsT Set Time: Use this o
DCSU 2911 E1 Craft Interface4-6Verilink DCSU 2911 User ManualConfiguration MenuType C on the Main Menu to display the DCSU 2911 Configuration Menu.Fig
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-7Timing Options SubmenuDisplay this menu by typing the command T from the top Configurati
DCSU 2911 E1 Craft Interface4-8Verilink DCSU 2911 User ManualTable 4-5 Dual CSU 2911 Timing ParametersCommand Description OptionsPS Primary Synchroniz
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-9Alternate Timing Options SubmenuIf the option, “Receive clock from shelf” has been selec
DCSU 2911 E1 Craft Interface4-10Verilink DCSU 2911 User ManualFigure 4-6 DCSU 2911 Diagnostic Menu Figure 4-7 Diagnostics Menu ParametersCommand Des
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-11When finished configuring the port diagnostics parameters, enter X to return to the Main
DCSU 2911 E1 Craft Interface4-12Verilink DCSU 2911 User ManualFigure 4-8 DCSU 2911 Performance/Status Menu Counter SubmenuFrom the Performance/Status
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-13Choosing X returns you to the Performance/Status Menu:Select P from the Performance/Stat
viVerilink DCSU 2911 User Manual
DCSU 2911 E1 Craft Interface4-14Verilink DCSU 2911 User ManualNet Port Alarm Threshold Status SubmenuEnter T from the Performance/Status Menu to acces
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-15Figure 4-12 DCSU 2911 Net Port Alarm Menu Following is a brief description of the alarm
DCSU 2911 E1 Craft Interface4-16Verilink DCSU 2911 User ManualFigure 4-13 DCSU 2911 Net Port Alarm Threshold Configuration Menu ConfigureThresholdsWhi
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-17 Net Port Alarm Threshold Configuration Menu ParametersCommand Description OptionsPn Ala
DCSU 2911 E1 Craft Interface4-18Verilink DCSU 2911 User ManualDisplay AlarmBuffersTo display the alarm buffer, enter O in the Net Port Alarm Menu. The
DCSU 2911 E1 Craft InterfaceVerilink DCSU 2911 User Manual4-19NOTE: The Manufacturing Information window provides useful information on the DCSU modul
DCSU 2911 E1 Craft Interface4-20Verilink DCSU 2911 User Manual
Verilink DCSU 2911 User Manual5-1Chapter5TroubleshootingController card(s) poll the various modules for alarms. If alarm reporting is enabled for the
Troubleshooting5-2Verilink DCSU 2911 User ManualAlarm DescriptionThe alarm description column lists the text which is:•printed on the display•sent to
TroubleshootingVerilink DCSU 2911 User Manual5-3What To Do About AlarmsSome alarms clear after the user-configured timeout has expired. Other alarms r
Table of ContentsDCSU 2911Verilink DCSU 2911 User Manual vDCSU 2911 Dual Channel Service Unit ...
Troubleshooting5-4Verilink DCSU 2911 User ManualAlarm ListFault conditions can result in critical, major, or minor alarms. In addition, a fault condit
TroubleshootingVerilink DCSU 2911 User Manual5-5Loss of Frame Alignment (E1 Only)This condition occurs when three consecutive in-error frame alignment
Troubleshooting5-6Verilink DCSU 2911 User ManualInterpreting Front Panel LEDsThe LED indicators on the front panel of the DCSU 2911 module display err
TroubleshootingVerilink DCSU 2911 User Manual5-7Data Port LEDsData Port LEDs display alarm conditions detected at the data ports. Data Port LEDs 1 and
Troubleshooting5-8Verilink DCSU 2911 User Manual
IndexVerilink DCSU 2911 User Manual Index-1Numerics1/8test pattern 3-14, 4-112N1 5-1test pattern 3-14, 4-112N20-1test pattern 3-14, 4-113 in 24 3-14,
Index-2 Verilink DCSU 2911 User Manualthresholds 3-19, 4-15Connecting Terminal 2-2connector interface module (CIM)specifications 1-3T1 1-3connector in
Verilink DCSU 2911 User Manual Index-3net port alarm menu 3-18, 4-15node administration 4-5performance/status 3-16, 4-13T1 port diagnostics 4-10passwo
Index-4 Verilink DCSU 2911 User Manual
VERILINK CORPORATION127 JETPLEX CIRCLE, MADISON, ALABAMA 35758TEL: (800) 837-4546September 1999P/N 880-502647-001-C1
Verilink DCSU 2911 User Manual viConfiguration Menu .......
Verilink DCSU 2911 User Manual1-1Chapter1DCSU 2911 Dual Channel Service UnitThe DCSU 2911 is an AS2000 application module that provides two network po