Following is a brief description of the configure threshold
parameters:
Table 3-11
Net Port Alarm Threshold Configuration Menu Parameters
Command Description Options
Pn Alarm Reporting: When alarm reporting is enabled, it will convey any
messages indicating alarms for each port. These alarms are declared to
both the Craft interface as well as the Node Manager (if used). If this option
is set to
No
, even if alarm reports for individual ports are requested, they
will not be reported. The LEDs will still turn amber or red in an alarm
condition. This option is best set to No while setting up or reconfiguring
your node, and then set to Yes during normal operation.
Yes or No
(Y/N)
Fn Loss-of-Frame (LOF) Threshold/LOF Interval: Use this option to indicate an
interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
3—86400
seconds
Ln Loss of Signal (LOS) Threshold/LOS Interval: Use this option to indicate an
interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
3—86400
seconds
Rn Remote Alarm Indication (RAI) Threshold/RAI Interval: Use this option to
indicate an interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
An Alarm Indication Signal (AIS) Threshold/AIS Interval: Use this option to
indicate an interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
Bn Bipolar Violation (BPV) Threshold/BPV Interval: Use this option to indicate
an interval that is larger than the threshold.
Threshold:
1—86400
0 to disable
Interval:
1—86400
seconds
En Errored Seconds (ES) 15 min. Threshold/ES 24 hr. Threshold: An ES alarm
indicates a second with one or more errors.
15 minute
Threshold:
1—900
0 to disable
24 hour
Threshold:
1—86400
0 to disable