Displaying circuit status
Access Manager 2000 User Manual
8-25
A status diagram like the one below will appear.
All possible error indications are shown in the screen above.
2. After viewing the current status diagram, press to return to
the On-line Access Menu.
Alarms are shown at the location at which they occur. If alarms are
present, the DS1 line section in alarm appears in flashing red. If no
alarms are present, the line section is green (or blank if you are
using a monochrome display). Alarm designations are shown
flashing adjacent to the circuit section in which they occur.
Any change in status reported by the near-end CSU causes the
screen to be updated.
These display information when a circuit
and far-end circuit elements are defined.