Configuration Options for AS2000 and ConnecT1 Plus
Access Manager 2000 User Manual
5
-
81
Go the the Alarm Set Delay Time field, and select the delay
time in the range of 0 to 255 seconds.
The default value for the this option is 3 seconds.
5. Decide how soon an alarm condition will clear.
Go to the Alarm Clear Delay Time field, and select the delay
time in the range of 0 to 255 seconds.
The default setting for the this option is 10 seconds.
6. Decide how soon an LOF alarm will clear.
Go the the Alarm Clear Delay Time for LOF field, and
select the delay time before a loss of frame (LOF) alarm condition
clears. Choose a value in the range of 0 to 255 seconds.
The default is 10 seconds.
Set this option to one of the following:
Use this option to define the time period after which an RLB releases.
Choose the setting desire from the following list:
DISABLE
xx SE , where xx = 01 to 59
Option Description
NO POLL
At both ends, to disable alarm polling. Select this option (the
default) when the nodes at both ends are connected to Access
Manager and both nodes report local alarms. Otherwise, the
same alarm is reported to Access Manager twice.
POLL
To have the near-end CSU automatically poll the far-end CSU
for alarms every four seconds and report those alarms to
Access Manager.
UNSOL
To have the far-end NCC, CCC, or TAC automatically (when it
detects a Loss of Signal) send its alarm status to the near-end
NCC, CCC, or TAC.
Select this option for the far-end CSU circuit element when the
near-end CSU is set to
POLL
.
Poll Far-End Statu
RLB Loopback
Time-out