Verilink 8100A (34-00237) Product Manual Manual de usuario Pagina 209

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 311
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 208
Reports 5-25
Display G7070 ADSL Statistics (81xx)
This report displays ADSL statistics.
Rx Cells Discarded No. of received cells discarded due to:
- Unknown VPI/VCI numbers
- Bad cell headers
- Size of cells received is larger than PDU size
- Other reasons as required
Cells Tx No. of valid ATM cells sent
OAM Tx No. of cells transmitted with CLPI (Cell Loss Priority
Indication) bit on
CLPI Tx No. of OAM (Operation And Maintenance) cells
transmitted
EFCI Tx No. of cells transmitted with EFCI (Explicit Forward
Congestion Indication) bit on
RM Tx No. of RM (Resource Management) cells transmitted
Rx HEC Errors No. of cells receives with HEC errors in the header
Lost Cell Delineation (OCD) No. of times cell delineation was lost
Time in OCD Amount of time in OCD condition
ATM Sync Current ATM Synchronization status—Established or
Lost
Parameter Description
Operational Seconds Total kernel time (in seconds) link was operational
Downstream SNR Margin Current rate of downstream SNR (Signal-to-Noise
Ratio) margin
Downstream Attenuation Current rate of downstream attenuation
Upstream Attenuation Current rate of upstream attenuation
Near-End FEC Count of near-end forward error correction
Near-End CRC Count of the near-end interleaved symbols with cyclic
redundancy check errors
Near-End SEF Count of near-end severely errored frames
Near-End LOS Count of near-end loss of signal frames
Far-End FEC Count of far-end forward error correction
Far-End CRC Count of far-end cyclic redundancy check
Far-End SEF Count of far-end severely errored frames
Far-End LOS Count of far-end loss of signal frames
Field Description