Configuration 4-33
Configure Transmit
CIR
To configure Transmit CIR, follow the steps below.
1 Type “1” on the Frame Relay DLCI Options menu to select Configure
Transmit CIR. The IAD prompts you to enter the Committed Burst Size
(Bc).
2 Type the Bc in number of bits. The IAD prompts you to enter the Circuit
Throughput.
3 Type the Circuit Throughput and press Enter. The IAD prompts you to enter
the Excess Burst Size (Be).
4 Type the excess burst value in number of bits and press Enter. The IAD
displays the Frame Relay DLCI Options menu (Figure 4.49).
5 Press Escape to return to the Frame Relay DLCI Config menu and continue,
or proceed to the next section.
Configure Receive CIR
To configure Receive CIR, follow the steps below.
1 Type “2” on the Frame Relay DLCI Options (Figure 4.49) menu to select
Configure Receive CIR. The IAD prompts you to enter the Bc.
2 Type the Bc in number of bits. The IAD prompts you to enter the Circuit
Throughput.
3 Type the Circuit Throughput in bits per second and press Enter. The IAD
prompts you to enter the Be.
4 Type the Be value in number of bits and press Enter. The IAD displays the
FR DLCI Options menu.
5 Press Escape to return to the Frame Relay DLCI Configuration menu and
continue.
Configure FRF.12
Fragmentation
To configure FRF.12 Fragmentation, follow the steps below.
1 Type “3” on the Frame Relay DLCI Options menu (Figure 4.49) to display
the End-to-End Fragmentation menu (Figure 4.50).
Figure 4.50
End-to-End Fragmentation Configuration Menu
2 Type “1” to select End-to-End FRF.12, or type “2” to manually set the
fragment size. If you type “1”, the IAD displays the status and prompts you
to enable or disable End-to-End FRF.12. If you type “2, the IAD prompts
you to enter the maximum fragment size.
3 Type the fragment size in bytes and press Enter. The IAD displays the End-
to-End Fragmentation Configuration menu. Press Escape to return to the
DLCI Configuration menu.
Modify Existing DLCI
To modify an Existing DLCI, follow the steps below.