4-16 FrameStart FSM
NOTICE: Always verify that a DHCP server is available on the network before
enabling DHCP Client. If, on power-up, a DHCP server is not found, a
60-second timeout will occur.
Client Identifier
Displays a unique identifier for a specific IP address.
Physical Address
Displays unique MAC address.
NOTICE: Always verify that a DHCP server is available on the network before
enabling DHCP Client. If, on power-up, a DHCP server is not found, a
60-second timeout will occur.
NOTICE: If you manually change the IP address, you must “Save and Restart.”
(See Save and Restart on page 4-6.)
Supervisory Configuration Screen
The Supervisory Config screen (Figure 4.11) displays the current speed of the
Supervisory port interface.
Figure 4.11
Supervisory Config Screen
The Supervisory screen lets you view and change the Supervisory port speed.
The Supervisory port only supports asynchronous character formats.
Speed
Changes the Supervisory port speed (in bits per second).
Values: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Default: 19200
Character Size
Selects the number of bits required to make up one asynchronous character.
Values: Five, Six, Seven, Eight
Default: Eight