Verilink FrameStart FSM (34-00299.E) Product Manual Manual de usuario Pagina 139

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 153
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 138
A-1
A PPENDIX
A
A
PP ENDIX
A
S
PECIFICATIONS
Network Interface
Line Rate: 1.544 Mbps (±50 ppm)
Line Framing: D4 or ESF
Line Code: AMI or B8ZS
Input Signal: DS1, +1 to 27 dB (ALBO)
Connection: RJ-48C jack, 100 (±5%)
Output Signal: 3.0 V (±10%) base-peak into 100 with protection
Mode: Long-haul, Short-haul
DSX-1 Level: 0-110, 111-220, 221-330, 331-440, 441-550, 551-660,
>661 ft
Line Build Out: 0, 7.5, 15, 22.5 dB attenuation
Transient Voltage: 1000 V protection, fused input/output
Jitter Control: per TR 62411 and T1.403
Timing Source: Internal, Network, Serial
Ones Density: B8ZS, Nx56K bit stuffing, alternate fill; complies with
TR 62411
Serial Interface
Connection DB-25 female
DTE Ports: Selectable RS-530, RS-232, or V.35
Data Rate: Synchronous, nx56 kbps or nx64 kbps (where n = 1–32)
Clocking: Internal, External
Management Interfaces
10/100 Ethernet
Connection: 8-pin modular
Network Protocol: TCP/IP based networks