B-2 FrameStart FSM
rfc2863.mib describes generic objects for network interface sub-layers
(This MIB is an updated version of MIB-II's ifTable, and
incorporates the extensions defined in RFC 1229.)
rfc2493.mib provides textual conventions to be used by systems
supporting 15-minute based performance history counts
rfc2115.mib describes the use of a Frame Relay interface by a DTE
rfc2495.mib describes DS1, E1, DS2 and E2 interfaces objects
rfc2011.mib for managing IP and ICMP implementations, but excluding
their management of IP routes
rfc2012.mib for managing TCP implementations
rfc2013.mib for managing UDP implementations
rfc2096.mib for the display of CIDR multipath IP routes
rfc2571.mib the SNMP Management Architecture MIB
The FrameStart FSM supports the following Enterprise-specific MIBs:
ds8200tc.mib textual conventions used by DS8200 MIB
ds8200v2.mib provides T1 configuration and statistics information
ipadv2.mib provides Frame Relay and PPP configuration and statistics
ipstart.mib MIB module for synchronous PPP
These MIB files may be found on the Verilink Documentation CD included
with the unit.
SNMP Trap Configuration
The FSM supports up to eight IP destinations for SNMP traps. These may be
configured either through the Web interface or through an SNMP
management application. For configuration of these destinations through an
SNMP management application, use a MIB browser to access the table
trapdest within ipadv2.mib and set the IP addresses of the host
computer running the management application(s). Entering an IP address of
0.0.0.0 will disable the entry.
Generic MIB Loading Instructions
The MIBs were written using the standard ASN.1 notation. Any standard SNMP
manager should be able to compile the MIBs. Although the exact procedure for
loading MIBs may vary from one platform to another, the following basic steps
are the same.
1 The SNMP manager has a directory for MIBs. Copy the files
ds8200tc.mib, ds8200v2.mib, ipadv2.mib, ipstart.mib,
router.mib, and hds12.mib into this directory. The MIBs use a
DOS format; therefore, a DOS2UNIX command may have to be used for
UNIX workstations (typical directories are snmp_mibs for HP’s