VT100 Interface 4-13
CAUTION: Performance data will be lost upon power cycle or after performing a
Maintenance Reset/Restart.
Serial Screens
The Serial 1 and Serial 2 screens on the WANsuite 5160 or Serial screen on
the WANsuite 5130 let you view and make changes to the unit’s Serial
interface configuration as described below. The parameters on all Serial
screens are the same except for the Invert Clock parameter, which is found
only on the Serial 2 screen; therefore, the WANsuite 5160 Serial 2 screen
(Figure 4.11) is the only one shown below.
To make changes to any Serial parameter, simply set the parameter to the
desired selection and press the “Esc” key.
Figure 4.11
Serial 2 Screen
Type
This parameter selects the type of interface (based on its electrical signal
characteristics) used by the equipment connected to the Serial port.
Values: V.35, RS-232, EIA-530
Default: V.35
NOTICE: V.35 requires the use of an optional cable. Refer to Appendix A,
“Specifications,” for ordering information.
Mode
By default, the Serial port serves as a DCE port in both Packet and TDM
modes. However, the Serial port can serve as a DTE port when the unit is in
Packet mode.
If the Serial port connects to a DTE device (such as a FRAD or a router), the
Mode parameter must be set to “DCE.” If this port connects to a DCE device