iWANsuite® 5650Reference ManualMay 200234-00314.E
x WANsuite 5650Typographic ConventionsThe following table lists the graphic conventions used throughout this guide.Customer Service and Technical Supp
Preface xiIf these toll-free numbers are not supported in your dialing area, you may call Verilink by direct dialing 1-256-327-2001.E-mailYou can requ
xii WANsuite 5650
About the WANsuite 5650 1-1CHAPTER1CHAPTER 1ABOUT THE WANSUITE 5650IntroductionThe telecommunications network service market is rapidly changing, wher
1-2 WANsuite 5650flexibility or utilization of the SHDSL pipe is achieved by allowing for the assignment of the individual timeslots to the desired en
About the WANsuite 5650 1-3Front Panel The front panel of the WANsuite 5650 has four user-activated input control buttons and nine LED status indicato
1-4 WANsuite 5650initiate/terminate tests and the corresponding LEDs indicate the status of tests on this port only.When on the G.703 port selection,
About the WANsuite 5650 1-5Table 1.1LED Indicators LED LabelOffGreenAmberRedPOWERNo PowerPower applied to unitUnit in test mode.SHDSLMains Power OffTr
1-6 WANsuite 5650Rear Panel ConnectionsThe rear panel of the WANsuite 5650 has five connectors. From left to right (as shown in Figure 1.2 below) thes
About the WANsuite 5650 1-7Supervisory PortThe SUPERVISORY PORT is a DB-9 female DCE connector configured for 8 bits, no parity, and 1 stop bit. Bit r
iiWANsuite 5650Copyright NoticeCopyright © 2002 Verilink Corporation. All rights reserved. No part of this publication may bereproduced, transmitted,
1-8 WANsuite 5650
Installation 2-1CHAPTER2CHAPTER 2INSTALLATIONThis chapter describes the contents of your WANsuite 5650 shipment and provides information on connecting
2-2 WANsuite 5650
VT100 Interface 3-1CHAPTER3CHAPTER 3VT100 INTERFACEIntroductionThis chapter describes the menus and options associated with the WANsuite 5650’s VT100
3-2 WANsuite 5650Cursor ControlsThe VT100 interface uses a blinking cursor to select various menus and then to select sub-menus and/or fields within t
VT100 Interface 3-3entry to be replaced by the new characters. To edit an existing entry rather than replace it, press the right arrow key to move the
3-4 WANsuite 5650System ScreenThe first option on the Main menu screen is the System screen (Figure 3.3). This screen lets you view and set specific i
VT100 Interface 3-5Download App CodeUse the “Download App Code” field to upgrade the software in your WANsuite 5650 unit. The revision level for the s
3-6 WANsuite 5650Figure 3.4Confirmation Screen NOTICE: Performing a “Maintenance Reset” or a “Save and Restart” will terminate communications with the
VT100 Interface 3-7Interfaces ScreenThe Interfaces screen displays a list of all the unit’s available interfaces as shown in Figure 3.5. Figure 3.5Int
iii•When the power supply cord or plug is damaged or frayed.•If liquid has been spilled into the product.•If the product has been exposed to rain or w
3-8 WANsuite 5650Figure 3.6SHDSL ScreenUnit TypeSelects the unit type. TU-R represents a CPE terminal unit; TU-C represents a CO terminal unit. The T
VT100 Interface 3-9Expected RepeatersThis field is used to provision the number of repeaters in the selected span.Values:0, 1, 2, 3, 4, 5, 6, 7, 8 Def
3-10 WANsuite 5650Configuration Profiles ScreenSelecting the Configuration Profiles function field from the SHDSL screen will display the following sc
VT100 Interface 3-11Figure 3.8Configuration Details ScreenThis screen allows the user to view and change various parameters of the selected Configurat
3-12 WANsuite 5650Alarm Profiles ScreenSelecting the “Alarm Profiles” option on the SHDSL screen will display the following screen:Figure 3.9Alarm Pro
VT100 Interface 3-13Alarm Profile Details ScreenThe Alarm Profile Details screen (Figure 3.10) is accessed by moving the cursor over a profile name in
3-14 WANsuite 5650LOSWSThis field configures the threshold for the number of Loss of Sync Word (LOSW) Seconds within any given 15-minute performance d
VT100 Interface 3-15Figure 3.12Span Endpoint Details Screen This screen provides details on the following span endpoint parameters: Vendor IDDisplays
3-16 WANsuite 56503.13), Span Endpoint Performance Screen(s) (Figure 3.14), and the Alarm Profiles screen (Figure 3.9).Span Endpoint Maintenance Scree
VT100 Interface 3-17Power SourceThis field indicates the DC power source being used by the associated unit.Restart EndpointThis field enables the mana
ivWANsuite 5650
3-18 WANsuite 565015-Minute and 1-Day Intervals ScreensAlso included on the Span Endpoint Performance screen are options to view the span endpoint per
VT100 Interface 3-19CRC4 ModeUsed to disable or enable CRC-4 detection/generation towards the SHDSL network. When less than 32 timeslots are configure
3-20 WANsuite 5650The table provides error status and alarm threshold information for the following error parameters:ESSets the Errored Seconds (ES) t
VT100 Interface 3-21The G.703 configuration screen provides the user-selectable prompts described in the table below. PerformanceThe Performance promp
3-22 WANsuite 5650Figure 3.17G.703 Performance 24-Hour Details Screen Select the “Performance 30 Day” prompt from the G.703 Performance 24 Hour screen
VT100 Interface 3-23Figure 3.19G.703 Performance 30 Day Details Screen Serial ScreenThe Serial screens let you view and make changes to the unit’s Ser
3-24 WANsuite 5650TypeThis parameter selects the type of interface (based on its electrical signal characteristics) used by the equipment connected to
VT100 Interface 3-25clock that is also supplied to the DTE as Transmit Clock. The “External” option uses the external clock from the DTE. Values:Inter
3-26 WANsuite 5650DTR Alarm ControlLets you set DTR Alarm Control parameters.Values:Permanent On, DTE DrivenDefault:Permanent OnDTR Alarm StatusLets y
VT100 Interface 3-27Supervisory ScreenThe Supervisory Configuration screen (Figure 3.21) displays the current speed of the Supervisory port interface.
vTable of ContentsPrefaceAbout this Manual ...
3-28 WANsuite 5650Service Table ScreenSelecting the “Services” option from the Main screen will display the Service Table screen shown below (Figure 3
VT100 Interface 3-29Service Details ScreenFigure 3.23Service Details Screen This screen allows the user to select and change the service parameters li
3-30 WANsuite 5650TDM Service Details ScreenSelecting the Channels function field from the SHDSL screen will display the TDM Service Details screen (F
VT100 Interface 3-31ApplicationsAccessed from the Main menu, The Applications screens describe diagnostics and traps for Layer 3 and above that do not
3-32 WANsuite 5650Figure 3.26Test Details Screen Loop TypeDescribes the type of loop test (if any) performed on the selected interface. Values:No Test
VT100 Interface 3-33The table shown in this screen lists each trap by its Index number, and displays the type of error captured by the trap (Trap Numb
3-34 WANsuite 5650
Front Panel Interface 4-1CHAPTER4CHAPTER 4FRONT PANEL INTERFACEIntroductionThis chapter describes the LED status indicators and control buttons associ
4-2 WANsuite 5650SELECT button, the port’s corresponding LED will flash. The status of the LLOOP and RLOOP LEDs will be the summary of the test states
Front Panel Interface 4-3LED IndicatorsThe table below describe the WANsuite 5650’s front panel LED indicators.NOTICE: The SHDSL, G.703, and Nx64 port
viWANsuite 5650Chapter 3 VT100 InterfaceIntroduction ...
4-4 WANsuite 5650
A-1APPENDIXAAPPENDIX ASPECIFICATIONSData InterfacesSHDSL PortLine Rate: 200 kbps–2056 kbpsLine Framing:Aligned 2.048 Mbps (G.991.2 E7)Line Code:Trelli
A-2 WANsuite 5650Supervisory PortConnection:DB-9 femaleData Rates:(bps) 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 (default: 38400 bps)Protoc
A-3Figure A.1G.SHDSL Loopback Diagrams WANsuite 5650Internal LogicNetworkPort(G.SHDSL)NetworkFramerG.703FramerG.703PortPortLogicNx64PortG.SHDSL Networ
A-4 WANsuite 5650Figure A.2G.703 Loopback Diagrams WANsuite 5650Internal LogicNetworkPort(G.SHDSL)NetworkFramerG.703FramerG.703PortPortLogicNx64PortG.
A-5Figure A.3Nx64 Loopback Diagrams WANsuite 5650NetworkPort(G.SHDSL)NetworkFramerInternal LogicG.703FramerG.703PortPortLogicNx64PortNx64 Network Side
A-6 WANsuite 5650Ordering InformationEach WANsuite 5650 unit is supplied with the following standard equipment: *Verilink Technical Support: toll-fre
A-7Connector Pin AssignmentsSerial Interface Pin Assignments (DCE Mode)The table below displays Serial Interface Pin Assignments for the DCE Mode. Fun
A-8 WANsuite 5650SHDSL Interface Pin AssignmentsThe SHDSL interface is a standard eight-pin modular jack. The table below displays the pinout assignme