Verilink WANsuite 7105 (34-00316.C) Product Manual Manual de usuario Pagina 229

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 255
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 228
VT100 Interface 4-95
Figure 4.90
HDLC Monitor Details Screen
Service Attached
Service to which an HDLC detector is assigned and for which statistics are
collected.
Values: Service Index, 0 = Disabled
Default: Disabled
NOTICE: A Serial 1 service can only be attached to Detector 1, and a Serial 2
service can only be attached to Detector 2.
Service (bps)
Bit rate of the service for which statistics are being collected.
Alarm Reset Timer
(sec)
Number of seconds a utilization alarm condition must not be present before
the unit resets the alarm. Zero (0) indicates the timer is disabled.
Values: 0900
Default: 30
Rx High Utilization
(%)
What the user considers Rx high utilization (expressed as a percentage) for
this service.
Values: 1100
Default: 75
Rx High Threshold
(sec)
Number of seconds Rx high utilization must be present before an alarm
reports.
Values: 0900
Default: 0 (Rx High Utilization Alarm Disabled)
Rx End of Day Low
Utilization %
What the user considers Rx low utilization at the end of the day for this
service.
Values: 0100
Default: 0 (Rx Low Utilization Alarm Disabled)
Vista de pagina 228
1 2 ... 224 225 226 227 228 229 230 231 232 233 234 ... 254 255

Comentarios a estos manuales

Sin comentarios