9111 Connections
25
9111
Port 1
T1 Option
This section describes the 9111 Internal T1 Card. The card is a one-port T1
interface card for the 9111 MultiPro series unit. The module has an RJ-48
connector and is located above the supervisory port as shown in Figure 2-4. The
internal T1 card is configured using the switches located on the rear panel.
Switch S1
.
Switch S1 is a 12-position
DIP switch located on the
rear panel of the 9111. This
switch provides the
configuration parameters
shown in Table 2-9 and
Table 2-10
Table 2-9
Switch S1
1-5
DSOs Assigned:
These five positions select the bit rate and the number of DSOs
assigned to the channel (see Table 2-10).
6
Rate Multiplier:
Sets the multiplier for the input timing (see Table 2-10). The unit
operates at any data rate that is a multiple of 56 or 64 kbps.
7
Channel Assignment:
The Contiguous mode assigns the channels as a block
beginning at DS0 channel 1. If Alternate is selected, channel assignments are made
with an idle channel following each data channel.
8
Timing Source:
This switch determines the unit’s clocking source.
9
Network Coding:
B8ZS or AMI. Because AMI mode is sensitive to zero-bit density,
B8ZS is recommended for a more robust configuration.
10
Network Framing:
D4 or ESF only
11,12
Network LBO:
These switches set the network signal level (in decibels) of data
transmitted towards the T1 facility. The signal level is determined as shown in Figure 2-5.
65431 2
56 kbps
Alternate
64 kbps
Contiguous
A
B
Network Clock
(Looped)
Internal Clock
(Master)
D4
ESF
B8ZS
AMI
LBO
Network
A A
B
A
B
A
B
B
0
-22.5
-7.5
-15
12119 1087
Figure 2-5
Switch S1
DS0s Assigned
(see Table 2-10)