OSPF Router ID
This 32-bit number assigned to each router running the OSPF protocol
uniquely identifies the router within an Autonomous System. Each router
requires a unique router ID. Default is the LAN IP address of the unit.
The IP Gateway screen provides the following prompts that may be selected
by pressing the “Enter” key:
Circuit Table Screen
This menu shows the configured circuit. To configure a new circuit, select
"Add New."
Figure 4.40
Circuit Table Screen
Circuit Details Screen
Access this menu by selecting the appropriate <Index> number from the
Circuit Table menu.The screen’s parameters are described in the paragraphs
that follow.
Prompt Function
RIP Parameters
Static Route Table Displays static and dynamic route information.
Static ARP Table Displays static ARP information.
Trusted Neighbors Displays trusted neighbors information.
OSPF Parameters
Area Table Displays area information.
Virtual Link Table Displays virtual link information.
Circuit Table Provides user access to circuit-related information/
operation.