Troubleshooting
Verilink HDM 2180 User Manual 6-5
C-bit Errored Second (CES)—A CES is a second with one or
more CCVs or one or more Out of Frame (OOF) defects or a
detected incoming AIS. This gauge is not increased when UASs
are counted.
Alarm Indication Signal Second (AISS)—A second when the
CSU receives an unframed all-ones alarm indication signal
(AIS) from the network.
Line Coding Violation (LCV)—An LCV error event is a count of
both bipolar violations (BPVs) and excessive zeros (EXZs)
occurring over the accumulation period. An EXZ increments
the LCV by one regardless of the length of the zero string.
Line Errored Second (LES)—An LES is a second in which one or
more LCVs occurred or one or more LOS defects.
Loss of Signal Second (LOSS)—A second during which the CSU
is in a Loss of Signal (LOS) state.
P-bit Coding Violation (PCV)—A P-bit parity error event is the
occurrence of a received P-bit code on the DS3 M-frame that is
not identical to the corresponding locally-calculated code.
P-bit Errored Second (PES)—A PES is a second with one or
more P-bit Coding Violations (PCVs) or one or more Out of
Frame defects or a detected incoming AIS. This gauge is not
increased when Unavailable Seconds (UASs) are counted.