5-8 WANsuite 5260/5230
unit alarms a loss of DTR, which occurs when the Serial port detects that the
DTR signal is low.
Reset Timer
This field is the contiguous number of seconds that an alarm parameter must
be clear before the alarm is reset. Applicable values range from 000 through
899. A value of “000” means that the alarm never resets. Press
SELECT to
change this threshold.
Reset Alarms
This option clears the alarm counts. To reset the alarms, press the SCROLL
button to bring up the “Yes” option, and then press the
SELECT button.
Performance Menu
The PERFORMANCE menu displays a history of the network error
parameters that are continuously monitored. This register lets you view the
24-hour performance totals from the unit. Although only the 5260’s
Performance menu is shown below in Figure 5.9, the parameters are the same
for the WANsuite 5260 Network 1 and Network 2 menus and also for the
Network menu in the WANsuite 5230.
Figure 5.9
WANsuite 5260 Performance Menu Tree
The parameters on this menu are the same as those on the Alarms Menu,
except for the three additional parameters defined below:
BES
Sets the Bursty Error Seconds (BES) threshold. A BES is a 1-second period
during which at least more than one but fewer than 320 CRC6 errors
occurred.
Net 1 24-hour
Perf
(read-only fields)
ES
SES
LOSS
OOFS
BPVS
CSS
RAS
AISS
UAS
CRCES
BES
LOFC
Net 1
Performance
Vista de pagina 203