Verilink QUAD T1 (880-503345-001) Product Manual Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 57
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
Quick Set-Up
2-6 Verilink QUAD T1 User Manual
Figure 2-5 Configuration Menu for Slot 4
10. Use "I1" to place port 1 into service. No other changes to the
module default settings are required for this example.
11. Use the "C" command and copy the settings for port 1 to all
ports.
12. Use the "T" command to access the timing submenu and verify
that the
R) receive clock from shelf:
R) receive clock from shelf:R) receive clock from shelf:
R) receive clock from shelf:
option is set to
yes
yesyes
yes
.
13. This completes the port configuration for this module. Exit to
the
Main Menu
by typing "X" twice.
Build Circuits
Once the required ports are configured and placed in service, the
circuits are built using the Circuit Build function of the SCM.
Always use the Craft interface of the SCM module, by direct
connection or Telnet, to access the Circuit Build function—instead
of connecting to the Craft interface of the individual modules. This
assures that the SCM remains the central repository of all circuit
routing information.
NOTE:
The assumption is made that the ports of the other modules
have been placed in service and configured. Always place
ports in service and configure them before building circuits.
-- QUAD T1 CONFIGURATION MENU --
-- QUAD T1 CONFIGURATION MENU ---- QUAD T1 CONFIGURATION MENU --
-- QUAD T1 CONFIGURATION MENU --
Port 1 Port 2 Port 3 Port 4
Port 1 Port 2 Port 3 Port 4 Port 1 Port 2 Port 3 Port 4
Port 1 Port 2 Port 3 Port 4
In) in service no no no no
In) in service no no no noIn) in service no no no no
In) in service no no no no
Fn) frame format ESF ESF ESF ESF
Fn) frame format ESF ESF ESF ESFFn) frame format ESF ESF ESF ESF
Fn) frame format ESF ESF ESF ESF
Ln) line coding B8ZS B8ZS B8ZS B8ZS
Ln) line coding B8ZS B8ZS B8ZS B8ZSLn) line coding B8ZS B8ZS B8ZS B8ZS
Ln) line coding B8ZS B8ZS B8ZS B8ZS
Bn) line build out 0db 0db 0db 0db
Bn) line build out 0db 0db 0db 0dbBn) line build out 0db 0db 0db 0db
Bn) line build out 0db 0db 0db 0db
En) equalization n/a n/a n/a n/a
En) equalization n/a n/a n/a n/aEn) equalization n/a n/a n/a n/a
En) equalization n/a n/a n/a n/a
NDn) network density none none none none
NDn) network density none none none noneNDn) network density none none none none
NDn) network density none none none none
NLn) network initiated loop no no no no
NLn) network initiated loop no no no noNLn) network initiated loop no no no no
NLn) network initiated loop no no no no
An) alarm declare time(sec) 0 0 0 0
An) alarm declare time(sec) 0 0 0 0An) alarm declare time(sec) 0 0 0 0
An) alarm declare time(sec) 0 0 0 0
DLn) FDL enable no no no no
DLn) FDL enable no no no noDLn) FDL enable no no no no
DLn) FDL enable no no no no
PRM enable yes yes yes yes
PRM enable yes yes yes yes PRM enable yes yes yes yes
PRM enable yes yes yes yes
Rn) enable inband/FDL no no no no
Rn) enable inband/FDL no no no noRn) enable inband/FDL no no no no
Rn) enable inband/FDL no no no no
Sn) trunk condition bits(A/B) 0/0 0/0 0/0 0/0
Sn) trunk condition bits(A/B) 0/0 0/0 0/0 0/0Sn) trunk condition bits(A/B) 0/0 0/0 0/0 0/0
Sn) trunk condition bits(A/B) 0/0 0/0 0/0 0/0
F) FDL configuration
F) FDL configurationF) FDL configuration
F) FDL configuration
C) copy port T) timing
C) copy port T) timingC) copy port T) timing
C) copy port T) timing
X) exit this menu
X) exit this menuX) exit this menu
X) exit this menu
A [0.0.0.2] [1,4] QUAD T1 >
A [0.0.0.2] [1,4] QUAD T1 >A [0.0.0.2] [1,4] QUAD T1 >
A [0.0.0.2] [1,4] QUAD T1 >
Vista de pagina 19