Quick Set-Up
Verilink QUAD T1 User Manual 2-3
Log-In
Connect a Craft cable to the port labelled
LOCAL
on the front of the
SCM module.
Connect the other end of the Craft cable to a notebook computer.
Start a session in a terminal program.
1. Set your terminal parameters to:
19.2 kbit/s
8 data bits
No parity
One stop bit
No flow control
2. Press
E
NTER
.
3. The prompt
pSH+>
pSH+>pSH+>
pSH+>
appears.
4. Type “craft” (use lowercase)
5. The prompt
Your Password
Your PasswordYour Password
Your Password
appears.
6. Initially there is no password, press
E
NTER
.
7. The
SCM Main Menu
appears.
8. To navigate to the first QUAD T1 module (in slot 3), type “S”
and press
E
NTER
. At the prompt type “1,3” and press
E
NTER
.
NOTE:
For the rest of this chapter, you will not be instructed to press
E
NTER
after each command. Generally,
E
NTER
is used after
each keyboard entry.
Configure Ports
Each port used in this example must be configured correctly and
placed in service. The
Configuration Menu
is used for this
purpose. With the first QUAD T1 module selected, access the
Configuration Menu
by typing "C" at the
Main Menu
. Figure 2-3
shows the QUAD T1
Configuration Menu.
In the example
Configuration Menu
shown in Figure 2-3, ports 1
and 2 offer line build out options while ports 3 and 4 offer
equalization (cable length) options. This is because a CIM 3003 is
used. The CIM 3003 features two DS-1 ports and two DSX-1 ports.
This is correct for this example because we are connecting ports 1
and 2 to T1 circuits, and port 3 is connecting to a PBX which
presents a DSX-1 interface. Port 4 of the first QUAD T1 module is
not used in this example.