NetEngine IAD User Guide
WAN Configuration 77
Figure 4–31. E1 Configuration menu
Type the option to set the frame mode.
2. The IAD saves the configuration, resets the interface and displays the
menu. (The menu and reset messages may conflictpress any key to
refresh the menu.)
3. Press Escape to return to the E1 Configuration menu and continue
with other configuration tasks.
4. Reset the IAD (page 15) when you finish E1 configuration.
Setting Line Build Out
1. Type 3 (Select Transmit Line Build Out) to display the Line Build Out
menu.
Figure 4–32. Select Line Build Out Menu
Type the option to select the line build out decibel setting.
2. The IAD resets the interface and displays the menu.
3. Press Escape to return to the E1 Configuration menu and continue
with other configuration tasks.
4. Reset the IAD (page 15) when you finish E1 configuration.
Configuring S-Bits
The E1 Configuration menu displays.
1. Type 4 to select Configure S-Bits.
2. The IAD displays the Configure S-Bits menu and current settings.
*******************************************
Select E1 Frame Mode
*******************************************
E1 Frame Mode = FAS
1. FAS
2. FAS (CRC4 Enabled)
3. Multi-Frame CAS
4. Multi-Frame CAS (CRC4 Enabled)
**********************************
Select Line Build Out
**********************************
Line Build Out Is 0 dB
1. 0 dB
2. -7.5 dB
3. -15 dB
4. -22.5 dB