Verilink WANsuite 7205 (34-00317.B) Product Manual Manual de usuario Pagina 204

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 221
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 203
4-82 WANsuite 7205
The Bridge Details screen shown in Figure 4.78 lets you access and configure
the parameters described below.
Figure 4.78
Bridge Details Screen
From this screen, you may view the parameters described below.
Enable
Enables or disables Bridging capability.
Values: Enable, Disable
Default: Disable
Group Multicast MAC
Address
MAC Address recognized by the Bridge as the group address for the Bridge
Protocol Data Unit (BPDU) transfer between bridges.
Values: Any valid Group Multicast MAC Address
Default: 0180C2000000
Bridge ID
Consists of a bridge priority and its own MAC Address.
Values: 165535
Default: 2
Hello Timer
Specifies the BPDU broadcasting interval.
Values: 165535 s
Default: 10 s
Max Age Timer
Specifies the length of time a bridge will consider the network topology held
in memory as valid.
Values: 165535 s
Default: 60 s
Forward Delay
Specifies the length of time to delay creation of a temporary loop in the
network.
Values: 165535 s
Default: 5 s
Vista de pagina 203
1 2 ... 199 200 201 202 203 204 205 206 207 208 209 ... 220 221

Comentarios a estos manuales

Sin comentarios