3-82 WANsuite 7205
Figure 3.74
HDLC Monitor Details Screen
Service Attached
Service to which an HDLC detector is assigned and for which statistics are
collected.
Values: Service Index, 0=Disabled
Default: Disabled
NOTICE: A Serial 1 service can only be attached to Detector 1, and a Serial 2
service can only be attached to Detector 2.
Service bps
Bit rate of the service for which statistics are being collected.
Alarm Reset Timer
Number of seconds a utilization alarm condition must not be present before
the unit resets the alarm. Zero (0) indicates the timer is disabled.
Values: 0−900
Default: 30
Rx High Utilization
What the user considers Rx high utilization (expressed as a percentage) for
this service.
Values: 1−100
Default: 75
Rx High Threshold
Number of seconds Rx high utilization must be present before an alarm
reports.
Values: 0−900
Default: 0 (Rx High Utilization Alarm Disabled)
Rx End of Day Low
What the user considers Rx low utilization at the end of the day for this
service.
Values: 0−100
Default: 0 (Rx Low Utilization Alarm Disabled)