VT100 Interface 4-11
Line Probe
Enables or disables rate adaptation line probe.
Values: Enabled, Disabled
Default: Enabled
To change any configuration profile parameter, enter the desired value/
information in a field or select the desired parameter from one of the pull-
down lists, and then press the “Esc” key.
Alarm Profiles Screen
Selecting the “Alarm Profiles” prompt on the WANsuite 6450’s Network
Config screen will display the screen shown in Figure 4.10.
Figure 4.10
Alarm Profiles Screen
The Alarm Profiles screen displays the current values of SHDSL alarm
thresholds. Information is displayed for the following alarm parameters:
Alarm Profiles
Name associated with this Alarm profile.
Loop Atten
Loop attenuation threshold.
SNR Margin
Signal-to-Noise Ratio margin threshold.
ES
Errored Seconds threshold.
SES
Severely Errored Seconds threshold.
CRC
Cyclic Redundancy Check anomalies threshold.
LOSWS
Loss of Sync Word Second threshold.
UAS
Unavailable Seconds Threshold.