3-8 WANsuite 5165
The four columns of the status table are as follows:
The table provides error status and alarm threshold information for the
following error parameters:
ES
Sets the Errored Seconds (ES) threshold. An ES is a 1-second period in which
at least one logic error occurred. The default value is 45 seconds.
SES
Sets the Severely Errored Seconds (SES) threshold. An SES is a 1-second
period in which at least 320 CRC errors or one Out-of-Frame (OOF) error
occurred. The default value is 5 seconds.
LOSS
Sets the Loss of Signal Seconds (LOSS) threshold. A LOSS is a 1-second
period in which the T1 received signal is interrupted. The default value is 5
seconds.
UAS
Sets the Unavailable Seconds (UAS) threshold. A UAS is a 1-second period
in which consecutive severely errored seconds cause an unavailable state. The
default is 0 (zero) seconds (Disabled).
CSS
Sets the Controlled Slip Seconds (CSS) threshold. The default is 0 (zero)
seconds (Disabled).
BPVS
Sets the Bipolar Violation Errored Seconds (BPVS) threshold. A BPVS is a 1-
second period in which at least one bipolar violation occurred. The default is
0 (zero) seconds (Disabled).
OOFS
Sets the Out of Frame Seconds (OOFS) threshold. An OOFS is a 1-second
period in which a frame sync loss occurred. The default value is 5 seconds.
AISS
Sets the Alarm Indication Signal Seconds (AISS) threshold. An AIS is a 1-
second period when unframed all ones are received. The default is 0 (zero)
seconds (Disabled).
RAS
Sets the Remote Alarm Seconds (RAS) threshold. A RAS is generated by the
terminal equipment when an improper signal is received from the facility (or
upon receipt of unframed all ones). The default is 0 (zero) seconds (Disabled).
Reset Timer
Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Status Displays the current status of the network port.
Alarm Displays the alarm value of the network port. The unit
declares an alarm as soon as the count exceeds the threshold
set.
Count Displays the number of events or occurrences of this statistic
that have been detected.
Threshold A read/write field that can be set to a desirable threshold.