Verilink PRISM 3060-10 (34-00252.4) Product Manual Manual de usuario Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
T1 NET Configuration 19
T1 NET
Configuration
The T1 NET Configuration screen (Figure 3-8) allows setting the following
network configuration parameters.
Defaults are shown underlined.
Framing Type Selects the framing for the T1 network. The choices are D4 and ESF
.
Line Code Sets the network side line coding. The choices are AMI and B8ZS
.
Line Build Out Sets the line build out for the network interface. The choices are 0 dB
, -7.5 dB,
-15 dB, and -22.5 dB.
Timing Sets the timing source to synchronize the unit’s internal timing generators. In all
cases, slips are controlled to occur on frame boundaries at the network and/or
DSX1 ports when timing synchronization is lost. The choices are as follows.
INTERNAL
The unit’s internal frequency standard is used for all timing.
NETWORK
Timing is derived from the network-recovered clock (the most common selection
for most applications).
STATION
Timing is derived from a bipolar- or TTL-compatible clock supplied to the unit
through the rear panel. This field shows the input timing and only appears when
Figure 3-7 T1 NET Configuration Menu
Framing
Type
Line
Code
Line
Build
Out
Timing
ESF
D4
AMI
B8ZS
0 dB
-7.5 dB
-15 dB
-22.5 dB
Internal
Network
T1 DTE
Station
Slot X /Port Y,
(where
X = 3 to 6 and
Y = A or B)
Station
Input
Timing
1.544
MHz
N
×
56 K
N
×
64 K
(Station
Timing
must be
selected)
Zero
Suppress
Enable
Disable
PRM
Enable
Enable
Disable
Alarm
Thresholds
Station
Timing
Selects the
N
multiplier
(1 - 24)
for the
Input
Timing.
Alarm Reset 030
ES 045
SES 005
LOSS 005
OOFS 005
UAS 000
RAS 000
AISS 000
BPVS 000
T1 NET Configuration
Line Code ............. AMI
<
Figure 3-8 T1 NET Configuration Screen
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 75 76

Comentarios a estos manuales

Sin comentarios