DSU MP Specifications 3
Environmental Operating Temp: 0° to 50°C(32° to 122°F)
Storage Temp: -20° to 85°C(-4° to 185°F)
Humidity: 95% maximum (non-condensing)
Compatibility TR 62411: December 1990
TR 41458: April 1990 (where applicable)
TR 54016: September 1989
T1.403: 1989
TR 54019A: April 1988
Industry
Listings
FCC Compliance: Part 15 Subpart B, Class A, Part 68
Industry Canada: CS03
US Safety: UL1459, 2nd Edition
Canadian Safety: CSA C22.2, No. 225-M90
DSU MP
Specifications
DDS I Port
Data Rate
Sync: 56 kbps
TXP I Port
Data Rates
NON-TDM: Async: 2.4, 4.8, 9.6, 19.2, 38.4, 52, and 57.6 kbps
Sync: 2.4, 4.8, 9.6, 19.2, 38.4, and 52 kbps
TDM: Async: 2.4, 4.8, 9.6, 19.2, and 31.2 kbps*
Sync: 2.4, 4.8, 9.6, 19.2, and 31.2 kbps*
DDS II Port
Data Rate
Sync: 64 kbps
TXP II Port
Data Rates
NON-TDM: Async: 2.4, 4.8, 9.6, 19.2, 38.4, 56, 57.6, and 60 kbps
Sync: 2.4, 4.8, 9.6, 19.2, 38.4, 56, and 60 kbps
TDM: Async: 2.4, 4.8, 9.6, 19.2, and 38.4 kbps*
Sync: 2.4, 4.8, 9.6, 19.2, and 38.4 kbps*
* Only one port (A or B) can be set to the highest rate at any given time. For
example, if Port A is set to the highest rate, Port B can be set no higher than the
next highest rate.
Configuration Configuration: Front panel LCD, terminal interface on supervisory port,
telnet session through the TXPORT 8100A Site Controller.
SNMP management through the TXPORT 8100A Site
Controller.
Soft configuration is non-volatile.