Setting up REMS to provide re-sync to the encryptor
Red Zone Encryption Management System (REMS) User Manual
5-7
Setting up REMS to provide re-sync to the encryptor
Provide re-sync leads to the encryptor as follows:
1. Connect the encryptor re-sync leads to the relay alarm contacts on
the back of the FBR CIM 2020. (Use the COM and NC terminals.)
Make the re-sync connections from the FBR to the KG at both ends
of the circuit. (See Fig ure5-4, Providing Re-sync Leads to the
Encryptor.)
Figure 5-4 Providing Re-sync Leads to the Encryptor
2. Put the testset in loop-timing mode.
3. Using the thumbwheel interface, set the re-sync timing on the FBR.
See Chapter 6,
Configuring and starting REMS
. Start with 6 seconds
(command 71). Timing may vary depending on the encryptor and the
type of transmission facility used.
4. If the circuit is not working as indicated by the REMS LEDs, the
problem maybe in the network. Verify the T1 line by plugging an
ASCII terminal into the Craft interface on the near-end BRC NCC
2020 front panel. (For details, see
AS2000 ASCII Terminal Interface
Manual
.)
Common Carrier
or
Local Exchange
Networ
B
R
C
F
B
R
Encryptor
EIA 530
T1
B
R
C
KG
EIA 530
T1
To far end
Alarm relays
Re-sync leads
Tes t Set
Loop
Timing