Quick Set-Up
2-2 Verilink QUAD/IMUX User Manual
NOTE:
When more than one QUAD/IMUX is installed in the same
shelf all QUAD/IMUX installations in that shelf must use the
same timing source. Each QUAD/IMUX must have the
Receive
Receive Receive
Receive
clock from shelf
clock from shelfclock from shelf
clock from shelf
option set to
Yes
YesYes
Yes
. Each shelf may have only
one active timing source.
The IMUX 2160 in slot 4 uses 4 T1 circuits with a V.35 rear
interface module (DIM 2635). The IMUX 2160 in slot 9 uses 8
T1 circuits with a HSSI rear interface module (DIM 2660).
NOTE:
Since the V.35, RS-449 and EIA 530 electrical interfaces only
provide reliable operation at rates up to 6 Mbit/s, any
QUAD/IMUX installation which uses more than 4 T1 circuits
or more than 3 E1 circuits requires the use of a HSSI rear
connector module (DIM 2660) for the IMUX 2160. HSSI is
designed to provide reliable operation at up to 52 Mbit/s.
The DTE (Data Terminal Equipment) to be connected at each
site consists of TCP/IP routers. At the central site two different
WAN ports of the same router will be connected to the two
QUAD/IMUX installations.
All of the T1 circuits use ESF framing and B8ZS line coding.
Figure 2-1 Example Configuration