Configuration Menus
Verilink IMUX User Manual 3-3
Figure 3-2 IMUX Configuration Menu Options
Table 3-2 describes the
IMUX Configuration Menu
options and
Table 3-3 describes the status fields. The
IMUX Configuration
Menu
customizes to reflect the DIM attached to the back. The back
cards available are the HSSI (DIM 3664) and V.35 (DIM 3634).
Table 3-2 IMUX Configuration Menu
-- IMUX CONFIGURATION MENU --
-- IMUX CONFIGURATION MENU ---- IMUX CONFIGURATION MENU --
-- IMUX CONFIGURATION MENU --
FW Rev : 2.10
FW Rev : 2.10FW Rev : 2.10
FW Rev : 2.10
Line Type : T1 DSR) yes
Line Type : T1 DSR) yesLine Type : T1 DSR) yes
Line Type : T1 DSR) yes
Channel Rate : 64K CTS) no
Channel Rate : 64K CTS) noChannel Rate : 64K CTS) no
Channel Rate : 64K CTS) no
R) Rx Clk Phase: NORMAL DCD) yes
R) Rx Clk Phase: NORMAL DCD) yesR) Rx Clk Phase: NORMAL DCD) yes
R) Rx Clk Phase: NORMAL DCD) yes
T) Tx Clk Phase: INVERT RI) yes
T) Tx Clk Phase: INVERT RI) yesT) Tx Clk Phase: INVERT RI) yes
T) Tx Clk Phase: INVERT RI) yes
F) Ref Clk Phase: NORMAL TM) no
F) Ref Clk Phase: NORMAL TM) noF) Ref Clk Phase: NORMAL TM) no
F) Ref Clk Phase: NORMAL TM) no
H) DTE Handshake: AUTOMATIC
H) DTE Handshake: AUTOMATICH) DTE Handshake: AUTOMATIC
H) DTE Handshake: AUTOMATIC
DTE Type: V.35
DTE Type: V.35 DTE Type: V.35
DTE Type: V.35
Backplane Bus: D:A
Backplane Bus: D:ABackplane Bus: D:A
Backplane Bus: D:A
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Lines Equipped: X X
Lines Equipped: X XLines Equipped: X X
Lines Equipped: X X
Lines Active: X X
Lines Active: X XLines Active: X X
Lines Active: X X
Frame Sync: X X
Frame Sync: X XFrame Sync: X X
Frame Sync: X X
CTS Received: X X
CTS Received: X XCTS Received: X X
CTS Received: X X
CRC Error:
CRC Error:CRC Error:
CRC Error:
Far CRC Error:
Far CRC Error:Far CRC Error:
Far CRC Error:
X) main menu
X) main menuX) main menu
X) main menu
A [0.0.0.2] [1,5] IMUX >
A [0.0.0.2] [1,5] IMUX >A [0.0.0.2] [1,5] IMUX >
A [0.0.0.2] [1,5] IMUX >
Command V.35 HSSI Description Options
R X Rx Clk Phase—Receive clock phase. Most configurations require
normal.
1) Normal
2) Inverted
T X X Tx Clk Phase—Transmit clock phase. Most configurations require
inverted.
1) Normal
2) Inverted
F X X Ref Clk Phase—Reference clock phase. Most configurations
require normal.
1) Normal
2) Inverted
H X DTE Handshake—Selects the control lead mode. If manual mode
is selected, each control lead must be forced “On” or it will be
forced “Off”. If manual mode is selected, DSR must be forced “On”
or no user data is sent (never send data option).
In Automatic DTE handshake mode, each lead is asserted
according to the state of the complimentary lead. In automatic
mode, DSR is output high and user data is sent if the DTE asserts
DTR. In this mode, leads may not be forced “On” or “Off”.
1) Automatic
2) Manual