Configuration
3
-10
Verilink SCC 2020 User Manual
Drop And Insert
Mode
Drop and Insert mode combines the features of CSU mode and Mux
mode. The DSX-1 equipment port is used for some of the T1
timeslots and data bus A is used to pass other timeslots to some
DIU 21xx module(s). Since the CSU can not control the transmit
data rate of the DSX-1 equipment, the CSU is usually configured to
recover transmit clock from the DSX-1 datastream (THRU timing).
Drop and Insert mode is established by selecting
A, D&I NET
A, D&I NET A, D&I NET
A, D&I NET
for the
DIU bus option. When this is done, a new option field appears in
the
Configuration Menu
, beneath the PRM field, as shown below:
Figure 3-3 Select D&I DSOs Field
This field is used to select the timeslots for data use. Any timeslots
shown in this field will be placed on data bus
A
AA
A
for use by a
DIU21xx module. The DSX-1 equipment will receive a framed all-
ones signal in those timeslots, making them appear busy to a PBX.
Timeslots not listed in this field are allowed to pass unmodified to
the DSX-1 equipment.
Node Administration
In addition to the T1 CSU functions, the SCC 2020 is also an SNMP
node controller. The
Node Administration Menu
, and submenus
beneath it, are used to configure site, Ethernet and SLIP address
information.
Some functions on the
Node Administration Menu
support
firmware upgrade procedures.
Node
Administration
Menu
The
Node Administration Menu
is accessed by selecting O on the
SCC 2020
Main Menu
. Figure 3-4 shows the options presented.
Most of the commands on the
Node Administration Menu
are
documented in Table 3-5 below.
Some of the menu options on the
Node Administration Menu
will
produce submenus with detailed selections, for instance the
Modem Configuration Menu
is detailed in Table 3-6.
A) diu bus A,D&I NET
A) diu bus A,D&I NET A) diu bus A,D&I NET
A) diu bus A,D&I NET
P) prm OFF
P) prm OFF P) prm OFF
P) prm OFF
D) select D&I DS0s (1,-,24)
D) select D&I DS0s (1,-,24) D) select D&I DS0s (1,-,24)
D) select D&I DS0s (1,-,24)
_ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _
G) Alarm ENABLE
G) Alarm ENABLE G) Alarm ENABLE
G) Alarm ENABLE