2-4 Installation
PRISM 4001
B
OOT
M
ODE
Positions S2-7 and S2-8 select the startup boot configura-
tion method as shown in Table 2-N.
Configuration Switch S3
Switch S3 (Figure 2-4) sets the configuration parameters
listed in the following paragraphs.
NMS R
ATE
Positions S3-1 and S3-2 set the bit rate for the network
management system as shown in Table 2-O.
SUPV P
ORT
R
ATE
Positions S3-3 and S3-4 set the supervisory port rate as
shown in Table 2-P.
D
IAL
B
ACKUP
Position S3-5 can enable the unit’s dial backup feature as
shown in Table 2-Q.
DBU R
ATE
Positions S3-6 through S3-8 set the DBU port rate as shown
in Table 2-R.
Address Switch S4
Switch S4 sets the unit address. When using the 4001 with a
8100A Site Controller, each element in a group must have a
unique unit address. As many as 50 units (with addresses from
1 to 50) can exist in a group. If the unit is not connected to a
site controller, the NMS unit address should be left at the fac-
tory default setting of 1 where Position 1 is Up and all other
positions are Down (see Figure 2-5).
Switch S4 has eight positions used to create an 8-bit binary
code for an address in the range of 1 to 50. Switch position S4-
1is the least significant bit (LSB) and S4-8 is the most signifi-
cant bit (MSB). If a switch is down, its value is 0. If up, its
value is that of the upper location. the values are additive. For
example, to set a unit address to 5, position S4-3 (binary value
is 4) and position S4-1 (binary value is 1 would be set Up for a
unit address of 5 (4+1). All other positions would be set Down.
Interface Switches S5 and S6
Switches S5 and S6 are slide switches that set the unit to
either RS-232 or V.35. Both switches must be set to the
same selection (that is, RS-232 or V.35).
Table 2-N Boot Mode
Power-up Mode S2-7 S2-8
Boot from SAVED Down Down
Boot from DEFAULT Down Up
Boot from SWITCHED
Up Down
Boot from CONTROLLER Up Up
Table 2-O NMS Rate
NMS Rate S3-1 S3-2
19.2 kbps
Down Down
1.2 kbps Down Up
2.4 kbps Up Down
9.6 kbps Up Up
Table 2-P SUPV Rate
SUPV Rate S3-3 S3-4
19.2 kbps
Down Down
1.2 kbps Down Up
2.4 kbps Up Down
9.6 kbps Up Up
7654321 8
NMS
NMS
SUPV
DBU
DBU
Rate
Rate
Rate
Rate
DBU
Rate
Rate
SUPV
Rate
Switch
S3
DBU
Enable
Figure 2-4 Switch S3
Down Up
Table 2-Q Dial Backup
Dial Backup S3-5
Disabled
Down
Enabled Up
Table 2-R DBU Rate
DBU Rate S3-6 S3-7 S3-8
57.6 kbps
Down Down Down
2.4 kbps Down Down Up
4.8 kbps Down Up Down
9.6 kbps Down Up Up
19.2 kbps Up Down Down
38.4 kbps Up Down Up
7654321 8
LSB MSBBinary values
Down Up
1 2 4 8 16 32 64 128
0 0 0 0 0 0 0 0
Switch
S4
Figure 2-5 Switch S4