Installation 2-4
1558D APS CSU/DSU
O
PTION
S
WITCH
S3
Switch S3 is an eight position DIP switch used to configure
the 1558D unit address ID for the NET A hardware and the
NET B hardware. Unique addresses must be optioned for
each 1558D unit when multiple units are co-located and a
1559 Site Manager is being used. If no manager is being
used, the user should leave the DIP switches in the factory
default positions (all in the OFF or DOWN position). This
configures the unit for NET A address 1 and NET B address
2. Table 2-H indicates how to configure the address settings
for the first six 1558D units.
When connecting to the SUPV port using the
APS local access software, the 1558D NET A
and NET B addresses are viewed as a single unit
address and are displayed as 1.01 for addresses
1 and 2, 1.02 for addresses 3 and 4, etc.
O
PTION
S
WITCH
S4
Switch S4 is a ten position DIP switch used to configure the
following DTE interface options.
Set DSU Operating Speed (56kb - 1.536 Mbps)
Set Rate Multiple, 56kb or 64kb
Set DS0 Assignment Mode, Contiguous/Alternate
Set Flow Control, On/OFF
Set Data Invert, Yes/No
Switch 4, (Pos. 1 - 6) - These six DIP switches allow the
user to select the operating speed of the 1558D DTE port
and whether or not the DS0s are assigned sequentially,
beginning with DS0#1 or Alternately, beginning with
DS0#1, 3, 5, etc. The table below shows the option position
settings for the various combinations of speed and DS0
channel assignments. The 1558D can be configured to oper-
ate from 56 kb to 1.536 Mbps.
Switch 4 (Pos. 7 - 10) - These option switches are used to
set the following:
Contiguous or Alternate DS0 assignment
Set control lines to either ON or OFF
Enable or disable data invert feature
Table 2-J displays the various options/positions controlled
by SW4, positions 7 - 10.
5,6
Off
, Off
Off, On
On, Off
On, On
NET A LBO Value
0.0 dB
7.5 dB
15.0 dB
22.5 dB
7,8 Off
, Off
Off, On
On, On
On, Off
Network Clocking
Network Clocking
Internal Clocking
External DTE Clocking
Table 2-H Address Settings
*APS Mgr.
Unit Pos.
NET A/B
Address
Pos
1
Pos
2
Pos
3
Pos
4
Pos
5 - 8
1.01 1/2
Off
Off Off Off Off
1.02 3/4 On On Off Off Off
1.03 5/6 On Off On Off Off
1.04 7/8 On On On Off Off
1.05 9/10 On Off Off On Off
1.06 11/12 On On Off On Off
Table 2-G Switch S2
Position Selection Switch S2 Description
Table 2-I Speed Settings
Pos
1
Pos
2
Pos
3
Pos
4
Pos
5
Pos 6
Off
(64Kb)
Pos 6
On
(56Kb)
DS0
Off
Off Off Off Off 1536 1344 24
Off Off Off On Off 1472 1288 23
On Off Off On Off 1408 1232 22
Off On Off On Off 1344 1176 21
On On Off On Off 1280 1120 20
Off Off On On Off 1216 1064 19
On Off On On Off 1152 1008 18
Off On On On Off 1088 952 17
On On On On Off 1024 896 16
Off Off Off Off On 960 840 15
On Off Off Off On 896 784 14
Off On Off Off On 832 728 13
On On Off Off On 768 672 12
Off Off On Off On 704 616 11
On Off On Off On 640 560 10
Off On On Off On 576 504 9
On On On Of On 512 448 8
Off Off Off On On 448 392 7
On Off Off On On 384 336 6
Off On Off On On 320 280 5
On On Off On On 256 224 4
Off Off On On On 192 168 3
On Off On On On 128 112 2
On On On On On 64 56 1
Table 2-J Switch SW4-7 thru SW4-10
Position Selection Switch S4 Description
7Off
On
Contiguous DS0s
Alternate DS0s
8Off
On
Control Lines (CTS, DSR,CD) are set
to
On
Control Lines follow (DSR follows T1
sync, CTS follows RTS, and CD fol-
lows T1 density status)
9Off
On
Data Invert Disabled
Data Invert Enabled
10 Not Used