iTRANSPORT®34-002551st Edition1558D APSCSU/DSU
Installation 2-21558D APS CSU/DSUwire from the rear panel screw terminal labeled ‘GND’ to agood earth ground.Voltages in excess of 100 VDC may bepres
Installation 2-31558D APS CSU/DSUAC Power The 1558D unit operate from 115 VAC, 75 mA maximum.The unit is shipped with a 5.5 foot 3-prong industry sta
Installation 2-41558D APS CSU/DSUOPTIONSWITCHS3 Switch S3 is an eight position DIP switch used to configurethe 1558D unit address ID for the NET A ha
Installation 2-51558D APS CSU/DSUDS0 channel speed assignments are sequentiallyassigned beginning with DS0 #1 if SW4, Position7 is set to the OFF pos
Installation 2-61558D APS CSU/DSUAPS service is different from “normal” point-to-point T1service. The 1558D APS unit accepts a single source signalfr
Installation 2-71558D APS CSU/DSU• The Path Status, Alarm B (red) LED may be ON or OFFdepending on the alarm timer setting (0 to 900 seconds)configur
Installation 2-81558D APS CSU/DSUFigure 2-2 Local 1558D Test Diagram, Path A and Path BBantam Patch CordPath NET ASUPVSTATUSALOCKED BABALM LOS LPASE
Operation 3-11558D APS CSU/DSU3. OperationThe 1558D automatically switches a customer high speeddata application from a “defective” T1 service to a s
Operation 3-21558D APS CSU/DSU1558CO #1 CO #2155715571558DTET1, AIXC NetworkMasterSlave SlaveMasterT1, BT1, AT1, BIXC Local Loop APS application, bot
Operation 3-31558D APS CSU/DSUAPS Switching ParametersThe 1558D unit switches from the active line to the standbyline based upon user definable alarm
iiCopyright 1996 TxPORT, All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in aretrieval system,
Operation 3-41558D APS CSU/DSU• Occurrences - Intervals, 1 through 96 • Duration - Intervals, 1 through 96 • Valid Intervals Total • Occurrences, 24-
Operation 3-51558D APS CSU/DSUline. If the user momentarily moves the switch to either theA or B position and then returns the switch to the Auto pos
Operation 3-61558D APS CSU/DSUTEST LEDThis LED (tri-color amber, red, green) will indicate whenthe DSU portion of the 1558D has been placed in a TEST
Operation 3-71558D APS CSU/DSUThe 1558D will unloop after receiving a framed orunframed repeating T1 signal of (100) for ≥5 seconds.When the unit unl
Operation 3-81558D APS CSU/DSUPosition 7 - This DIP will be used to set the AMI/B8ZSfunction for NET A. The factory default setting is B8ZS.The 1558
Operation 3-91558D APS CSU/DSUDTE Control LinesThe DTE port can be optioned for control lines ON or fol-lows. When set to ON, the 1558D sets CTS, DS
Operation 3-101558D APS CSU/DSUBNETPowerCOM BusRxSupply±12 VDC+5 VDCTxLineDeframerNET AFramerLoopLine ProtectionFac/LocalLoopPLBAPSSelectPath A/BBrid
LAPS Operation 4-11558D APS CSU/DSU4. LAPS OperationAccess to key 1558D configuration, performance, and test-ing functions can be locally performed b
LAPS Operation 4-21558D APS CSU/DSURevisions: The LAPS software revision level is shownbelow the time. Refer to these numbers when contacting thefact
LAPS Operation 4-31558D APS CSU/DSUUSER LOG ONOnce the user has booted the LAPS software and connectedthe PC to the SUPV port of the 1558D unit, the
iiiTable of ContentsGeneral... 1-1Specifications...1-1T1 Network
LAPS Operation 4-41558D APS CSU/DSUline is the circuit name assigned by the user for the NET BT1 facility. Circuit names are defined by the user with
LAPS Operation 4-51558D APS CSU/DSUble from the three types of circuit screens discussed in thissection.Performance ScreenThe Performance screen (Fig
LAPS Operation 4-61558D APS CSU/DSUThe parameters shown on the PerformanceScreen are updated in one minute intervals. Anupdate may be forced by press
LAPS Operation 4-71558D APS CSU/DSUvalidity of the loop command. It is possible for the user tospecify a loop that is illegal (i.e. looping the activ
LAPS Operation 4-81558D APS CSU/DSUeters. If the screen is exited with a <N> response, reenteringthe Configuration Screen will show that all fi
LAPS Operation 4-91558D APS CSU/DSUBoot from: Displays the current setting of the APSswitches which determine the source of boot-time configu-ration
LAPS Operation 4-101558D APS CSU/DSU2. From the Maintenance screen, decide which Path is to belooped (A or B path).3. If necessary, force the 1558D t
LAPS Operation 4-111558D APS CSU/DSUTo unloop the unit, move the cursor highlight to the Unloopfield and toggle the field, using the space bar, until
LAPS Operation 4-121558D APS CSU/DSUthe target for testing, move the cursor highlight to the Loopfield and toggle the field, using the space bar, unt
LAPS Operation 4-131558D APS CSU/DSUseconds or more, after which, the NET device should beunlooped. NPC Payload LoopThe NPC Payload loopback is used
ivNear Payload Loop...4-10Near Line Loop ... 4-11Near Facility Loop ...
LAPS Operation 4-141558D APS CSU/DSUdesired test time. The choices are 15 minutes, 30 min-utes, 1 Hour, 24 Hours, and Continuous.4. After performing
I-1IndexNumerics1557 ADDRESS SETTINGS 2-3BBipolar Violations 3-1CCircuit List Screens 4-3Circuit ID 4-3Far 4-4Near 4-4Pos 4-3State 4-3Circuits in Alar
I-2Preservice TestingEnd - to - End 2-7Path A 2-6Path B 2-6RRevertive, Non - Revertive protection 3-1SService Select control 3-2SITE PREPARATIONS 2-1S
General 1-11558D APS CSU/DSU1. GeneralThe TxPORT 1558D APS CSU/DSU (Automatic ProtectionSwitch with integral V.35 DSU/CSU) provides the idealsolution
General 1-21558D APS CSU/DSUPowerUnit: 115 VAC, ≤75 mA, 35 BTU maximumMechanicalMounting: Desk, wall, or rack installation (comes with 19” rack mount
General 1-31558D APS CSU/DSUEnd users should use existing 48 VDC batterysources or a CSA certified power supply. Le present appareil numerique n’emet
General 1-41558D APS CSU/DSU
Installation 2-11558D APS CSU/DSU2. InstallationProper installation of the 1558D unit involves the followingkey steps:• Site Survey and Preparation•