SNMP Agent C-5PRISM 4151
ddsDteNoAlarm(1)
- DTE interface has no current
alarms
ddsDteDtrAlarm(2)
- DTE interface has currently
declared a loss of DTR alarm
ddsDteInterfaceType:
(read- only)
Reports the DTE interface type being used
ddsDteInterfaceV35(1)
- DTE interface is a V.35
ddsDteInterface232(2)
- DTE interface is a RS232
ddsDteInterfaceOther(3)
- DTE interface is something
other than listed above
ddsDteInterfaceNotAvail(4)
- DTE interface type is not
available
ddsDteV54Loop:
(read- write)
Allows you to select or verify the operational state of the
V.54 option
ddsDteV54LoopEnabled(1)
- The unit will currently
respond to V.54 loop codes
ddsDteV54LoopDisabled(2)
- The unit will not respond
to V.54 loop codes
ddsDteRtsCtsDelay:
(read- write)
Allows you to verify or select the delay used in the transi-
tion time on RTS and CTS. For the PRISM 4151, only the
ddsDteRtsCtsDelayNormal
and
ddsDteRtsCtsDelayLong
option are valid.
ddsDteRtsCtsDelayOff(1)
- Delay is turned off
ddsDteRtsCtsDelayNormal(2)
- Delay is a normal
amount based on the data rate and the hardware
ddsDteRtsCtsDelayLong(3)
- Delay is generally doubled
from the normal delay
ddsDteRtsCTSDelayUserDefined(30)
- Delay has been
user defined to some other value, when this value is set
the delay is set to 30ms
ddsDteRtsStatus:
(read- only)
Reports the current status of the RTS control lead
ddsDteRtsStatusHigh(1)
- RTS control lead is in the
active HIGH state
ddsDteRtsStatusLow(2)
- RTS control lead is in the
active LOW state
ddsDteCtsStatus:
(read- only)
Reports the current status of the CTS control lead
ddsDteCtsStatusHigh(1)
- CTS control lead is in the
active HIGH state
ddsDteCtsStatusLow(2)
- CTS control lead is in the
active LOW state
ddsDteDcdStatus:
(read- only)
Reports the current status of the DCD control lead
ddsDteDcdStatusHigh(1)
- DCD control lead is in the
active HIGH state
ddsDteDcdStatusLow(2)
- DCD control lead is in the
active LOW state
ddsDteDtrStatus:
(read- only)
Reports the current status of the DTR control lead
ddsDteDtrStatusHigh(1)
- DTR control lead is in the
active HIGH state
ddsDteDtrStatusLow(2)
- DTR control lead is in the
active LOW state
ddsDteDsrStatus:
(read- only)
Reports the current status of the DSR control lead
ddsDteDsrStatusHigh(1)
- DSR control lead is in the
active HIGH state
ddsDteDsrStatusLow(2)
- DSR control lead is in the
active LOW state
ddsDteDsrControl:
(read-write)
Allows you to review and configure the DTE DSR lead (Cir-
cuit 107/CC)
ddsDteDsrControlTestOff(1)
- DSR is on except when
the unit is in test
ddsDteDsrControlForcedOn(2)
- DSR is on regardless
of any unit condition
ddsDteDcdControl:
(read-write)
Allows you to review and configure the DTE DCD lead
(Circuit 109/CF).
ddsDteDcdControlIdleOff(1)
- DCD is on except when
the unit is receiving Idle Code from the network.
ddsDteDcdControlForcedOn(2)
- DCD is on regardless
of any unit condition
ddsDteRtsControl:
(read-write)
Allows you to review or configure the DTE RTS and CTS
leads (Circuit 105/CA and 106/CB).
ddsDteRtsControlNormal(1)
- RTS, Circuit Assurance,
and Antistreaming control CTS
ddsDteRtsControlForcedOn(2)
- RTS is ignored, CTS is
on regardless of any unit condition
ddsDteDtrAlarm:
(read-write)
Allows you to enable or disable monitoring on the DTR lead
(Circuit 108/CD).
ddsDteDtrAlarmEnabled(1)
- DTR low is an alarm con-
dition
ddsDteDtrAlarmDisabled(2)
- DTR is ignored
ddsDteRLDetect:
(read-write)
Allows you to override the DTE RL input pin on the
Remote Loopback lead (Circuit 140/RLB)
ddsDteRLDetectEnabled(1)
- RLB high activates the
Remote V.54 Loop
ddsDteRLDetectDisabled(2)
- RLB is ignored
ddsDteLLDetect:
(read-write)