3-2 Configuration
PRISM 4151
CTS Delay:
Switch S2-5 allows you to determine the CTS
delay as being either Short (Dn) or Long (Up).
RTS, CTS, DCD Handshake:
Switch S2-6 determines the
handshake process as either Force True (Dn) or Normal
(Up).
Remote/Local Loop:
Switch S2-7 disables (Dn) or enables
(Up) remote and local loop activation by the RL and LL pins
on the DTE interface.
DTE Alarm:
Switch S2-8 disables (Dn) or enables (Up) the
DTE alarm. The DTE alarm is generated when DTR from
the DTE device is false.
Software Configuration
The terminal interface is a firmware application program
embedded inside the PRISM 4151. You can access this
information through the LAN port (page 2-2), SUPV port
(page 2-3), or SLIP port (page 2-3) using a TELNET ses-
sion.
Interface Start-up
Once a compatible terminal is properly connected to the
unit, you can start a terminal interface session by sending a
BREAK command to the unit (or by pressing <return> four
times). If a password has been previously establish, you
must enter the correct password to continue the session.
The
password is case-sensitive.
If you have forgotten your pass-
word, note the date and time shown on your screen and con-
tact TxPORT Technical Support. You can establish a
password through the Utilities screen on page 3-10.
Once a valid password has been entered, the Main Menu
screen is displayed. If you are unfamiliar with the PRISM
4151 interface, commands, and menu structure, refer to
Appendix A,
Terminal Interface
, for specific information
concerning the menu structure and operator commands.
If you do not enter a keystroke for
10 minutes, the terminal interface
automatically logs off.
Configuration Screen
The Configuration screens allow you to view and set config-
uration parameters for the network elements.
To send a new configuration to the unit, you must
press <return> on one of the fields or exit the
screen. The underlined values are the factory
default parameters.
Table 3-H Timing Source
S2-3 S2-4 Timing Source
Dn Dn Network
Dn Up Internal
Up Dn DTE
Up Up Not Used
Alarm
Configuration
page 3-5
DTE Port
Parameters
page 3-4
SNMP
Configuration
page 3-7
Configuration Menu
Summary
page 3-9
TCP/IP
Configuration
page 3-6
Management
Ports
page 3-8
Figure 3-9 Configuration Menu
DDS Network
Parameters
page 3-3