34 APPENDIX A: MIB REFERENCE
PRISM
3301 MIB
{ 1.3.6.1.4.1.425.2.8.1 } The PRISM 3301 proprietary MIB contains the Network,
DTE, Current (current TR 54014 Performance Monitoring data), Interval (TR
54014 Performance Monitoring 15-Minute Intervals), and Total (TR 54014
Performance Monitoring 24-Hour Totals) tables.
t3NetTable
{ 1.3.6.1.4.1.425.2.8.1.1 } This table defines the PRISM 3301 Datalink
Configuration, Status, and Control Objects.
Object Name Object ID User Access Object Description
t3NetIndex t3NetConfigEntry 1 read-only The value for this object is equal to the value of IfIndex from the Interfaces
table of MIB II (RFC 1213).
t3NetLBO t3NetConfigEntry 2 read-write Line buildout level for DS3 interface.
1 - lbo_0
2 - lbo_150
3 - lbo_300
t3NetYellowXBit t3NetConfigEntry 3 read-write Representation of the yellow alarm.
1 - off
2 - on
t3NetAISPattern t3NetConfigEntry 4 read-write AIS can be represented in two forms. One is the standard DS3 blue alarm
with alternate 1's and 0's such as 1010...., and the other is all 1's used by
MCI. The default is blue.
1 - blue
2 - FAO
t3NetAISRxStuff t3NetConfigEntry 5 read-write Controls the AIS Rx-Stuffing option.
1 - off
2 - on
t3AISTxXBit t3NetConfigEntry 6 read-only Controls the value of the X-bit when transmitting AIS.
1 - zero
2 - one
t3Map t3NetConfigEntry 7 read-write This object is bit mapped. Set bits to select active timeslots as follows:
1 - Timeslot 1
2 - Timeslot 2
4 - Timeslot 3
8 - Timeslot 4
16 - Timeslot 5
32 - Timeslot 6
64 - Timeslot 7
128 - (RESERVED, must be 1)
Multiple bits can be set at the same time. Default all bits are set.
t3Scrambler t3NetConfigEntry 8 read-write Enable/Disable scrambler. The scrambler can be set for either 7 or 10 bit
scrambling. The default is off.
1 - off
2 - bit-7
3 - bit-10
t3Dsu t3NetConfigEntry 9 read-write The PRISM 3301 has the capability to route the incoming T3 signal to a
pair of AUX BNC connectors instead of to the DTE port. The values mean:
1 - Primary - The T3 signal path is to/from the DTE port. The AUX BNC
connectors are inactive.
2 - Secondary - The T3 signal path is to/from the AUX BNC connectors.
The DTE port is inactive.
t3NetLoopback t3NetConfigEntry 10 read-write This variable expands upon RFC1407 variable dsx3LoopbackConfig.
1 - dsx3NoLoop
3 - dsx3LineLoop
5 - dsx3FarProprietaryLoop - The unit at the other end was put into LINE
loop by this unit using a proprietary C-bit message.
t3NetStatus t3NetConfigEntry 11 read-only This variable expands upon RFC1407 variable dsx3LineStatus.
1024 - t3BPV
2048 - t3Parity
4096 - t3RemoteParity
8192 - t3Other