50 CHAPTER 4: TERMINAL OPERATION
Alarms Screen The Alarms screen (Figure 4-4) is used to view the alarm status of the network and
the DTE lines. The fields are described as follows.
NET/DTE Alarms These status lines display the selected element’s network/DTE signal alarm state.
Alarms are determined by the user-selectable thresholds listed in Table 4-2.
(Alarm status) The main body of the Alarms screen shows the count for parameters that can be
used to trigger an alarm.
The Current column shows the total of the preceding 15 one-minute intervals. At
the end of each one-minute interval, the oldest minute of the 15-minute interval is
discarded.
Figure 4-4 Alarms Screen
3030 DSU x.xx/x.xx PRISM 3030 Date: MM/DD/YY
3030 DSU x.xx/x.xx (Unit Address: 23) Time: HH:MM:SS
------------------------------------- ALARMS -----------------------------------
Element: [ ]
NET Alarms: OK
DTE Alarms: OK
Current Threshold
Loss of Signal Seconds (LOSS) 0 5
Errored Seconds (ES) 2 45
Severely Errored Seconds (SES) 2 5
Unavailable Seconds (UAS) 0 0
Out of Frame Seconds (OOFS) 0 5
Remote Alarm Seconds (RAS) 0 0
AIS Seconds (AISS) 0 0
BPV Seconds (BPVS) 0 0
DTE LOS/OOF Seconds (LOSS) 0 0
Power Loss Seconds (PLS) 0
Reset Alarm Registers: (RESET)
------------------------------------Messages------------------------------------
Local Screen
Table 4-2 Alarm Indications
Alarm Description
------- No status is available.
OK No alarm threshold has been exceeded, although
errors might exist that do not exceed thresholds.
ERRS The Errored Seconds, Severely Errored Seconds, or
Bipolar Errored Seconds threshold is exceeded.
LOSS The Loss Of Signal Seconds threshold is exceeded.
OOFS The Out Of Frame Seconds threshold is exceeded.
RAIS The Remote Alarm Seconds threshold is exceeded.
AISS The Alarm Indication Seconds threshold is exceeded.
UAS The Unavailable Seconds threshold is exceeded.