TRANSPORT
®
PRISM 3001
FT1/T1
CSU/DSU
34-00186
February 1998
Vista de pagina 0
1 2 3 4 5 6 ... 57 58

Indice de contenidos

Pagina 1 - PRISM 3001

TRANSPORT®PRISM 3001FT1/T1CSU/DSU34-00186February 1998

Pagina 2

1-6 GENERALCanadian Emissions RequirementsThis digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus s

Pagina 3 - Table of Contents

Ordering Numbers 1-7OrderingNumbersThis unit is shipped from the factory with the PRISM 3001 reference manual. The part numbers for the stand-al

Pagina 4

1-8 GENERALThe following optional accessories may also be needed for the installation and operation of the TxPORT PRISM 3001. Table 1-2 Optional Equ

Pagina 5 - Introduction

TxPORT Customer Service 1-9TxPORTCustomerService TxPORT 127 Jetplex Circle Madison, Alabama 35758 Telephone Numbers: 800-926-0085 or 205-772-37

Pagina 7 - 1-3

2INSTALLATIONIntroductionThis chapter contains information and instructions required to prepare the TxPORT PRISM 3001 for use. Included are initial in

Pagina 8

2-2 INSTALLATIONFor specific applications, additional cables and adapters may be required. The interface requirements of any application may be met by

Pagina 9 - FCC Requirements

Unit Configuration 2-3Therefore, when the unit is first received for installation or if power has not been applied for an extended period of tim

Pagina 10 - Warranty

2-4 INSTALLATIONNetwork CodingPosition S4-2 sets the network line coding to AMI or B8ZS. Down: AMI Up:B8ZSNetwork LBOPositions S4-3 and S4-4 set the l

Pagina 11 - Ordering

Unit Configuration 2-5If the Alternate channel mode is selected, channel assignments are made with an idle channel following each data channel.

Pagina 12 - 1-8 GENERAL

Copyright / Liability  1998 TxPORT, All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retriev

Pagina 13 - Service

2-6 INSTALLATIONNMS Bit RatePositions S6-1 and S6-2 are used to set the NMS port bit rate. This is a serial RS-232 DCE port configured for 8 bits, no

Pagina 14 - 1-10 GENERAL

Unit Configuration 2-7NET Framing: ESFDTE Framing: ESFNET Line Code: AMIDTE Line Code: AMITiming: Internal NET LBO: 0 dBDTE DSX level: 0 - 110 f

Pagina 15 - NSTALLATION

2-8 INSTALLATION20 out of the 24 possible bit rate configurations are available through these hardware settings. The missing rates are N×56 and N×64,

Pagina 16 - Configuration

Supervisory Port Connection 2-9SupervisoryPortConnectionThe front panel supervisory port serves several functions. A modem may be connected to t

Pagina 17 - S5 S4S6S7

2-10 INSTALLATIONNMSConnectionThe PRISM 3001 is fully compatible with the TxPORT EM8000 Element Manager and 8100A Site Controller. The EM8000 and 8100

Pagina 18 - Down 0 dB

NMS Connection 2-11All units on the same NMS chain must use the same NMS bit rate.NMSSplit CableThe EM8000 may be connected directly into the NM

Pagina 19 - Switch S6

2-12 INSTALLATIONT1 DTE PortConnectionThe 3001 provides an optional T1 DTE port interface for drop and insert applications. The DSX-output level shoul

Pagina 20

NET/External Clock Connection 2-13An alternate method of connecting the network is through the Network/External Clock contacts provided on the r

Pagina 21 - Unit Configuration

2-14 INSTALLATIONPin 5 is configured to operate in either a normally open (NO) or normally closed (NC) mode as determined by the setting of the alarm

Pagina 22

Power Connection 2-15Connect the -48 VDC lead to the -48 VDC terminal (18- to 20-gauge recommended). Connect the return lead to the 48 VDC retur

Pagina 23 - Supervisory Port Connection

iiiTable of Contents1 GeneralIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Features . . . . . . . . . . . .

Pagina 24 - Connection

2-16 INSTALLATIONTRANSPORT®3001CSU/DSUSTATUSACO SWSUPVACO1TRANSPORT®3001CSU/DSUSTATUSACO SWSUPVACO1TRANSPORT®3001CSU/DSUSTATUSACO SWSUPVACO1TRANSPO

Pagina 25 - NMS Connection

3OPERATIONIntroductionThis chapter contains general operation instructions for the TxPORT PRISM 3001 front panel. The unit may be controlled manually

Pagina 26 - T1 DTE Port

3-2 OPERATION4 RTS: This green LED lights when the request to send signal is active. 5 DTR: This green LED lights when the data terminal ready signal

Pagina 27 - NET/External

Front Panel Testing 3-315PLB: This LED lights continuously when the network interface is in a payload loopback. With LLB, this LED also lights c

Pagina 28 - D/I Option

3-4 OPERATIONBERTPatternSelectThis rotary switch determines the BERT pattern sent when the Test switch is in the FAR position. Table 3-1 shows the cor

Pagina 29 - 2-15

4TERMINALOPERATIONIntroduction This chapter describes the screens and menus associated with the TxPORT PRISM 3001 terminal interface, which is a firmw

Pagina 30 - Figure 2-11

4-2 TERMINAL OPERATIONCalling the PRISM 3001 and sending the break command before receiving the connect message hangs up the modem. ScreenComponentsTe

Pagina 31 - PERATION

System Description 4-3InterfaceStart UpOnce a compatible terminal is properly connected to the 3001, the terminal interface is started by sendin

Pagina 32 - 3001 Front Panel

4-4 TERMINAL OPERATIONFields without brackets or parenthesis are display-only fields. They cannot be changed on the screen. Most user-selectable field

Pagina 33 - Testing

Alarms Screen 4-5If no key is pressed for 10 minutes, the terminal interface logs off automatically. To manually log off, press Escape from the

Pagina 34 - DTE Interface

ivInterface Start Up . . . . . . . . . . . . . . . . . . . . . . . . . .4-3Cursor Contros . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Pagina 35

4-6 TERMINAL OPERATIONNET/DTEAlarmsThese status lines display the selected elements current network/DTE signal alarm state. Alarms are determined by t

Pagina 36 - Password Screen

Performance Screens 4-7PerformanceScreens The Performance screens display a detailed history of the error parameters that are continuously monit

Pagina 37 - System Description

4-8 TERMINAL OPERATIONUSER DTEDisplay the user performance registers for the T1 DTE.TELCO NETDisplay the telco performance registers for the network.T

Pagina 38 - Main Menu

Performance Screens 4-9(performancedata)The main body of display data consists of error events for three different periods: The first display li

Pagina 39 - Alarms Screen

4-10 TERMINAL OPERATIONMaintenanceScreen The Maintenance screen (Figure 4-6) allows the user to perform test and maintenance functions on the T1 circu

Pagina 40 - 4-6 TERMINAL OPERATION

Maintenance Screen 4-114NET MLB:The network maintenance loopback command loops data at the T1 DTE port back toward the network (passes network d

Pagina 41 - Screens

4-12 TERMINAL OPERATIONFigure 4-8 Loopback DiagramsNetwork PLBNetwork Interface Framer/Deframer Multiplexer Receivers/DriversNETPLBReceivers/Drivers

Pagina 42 - (NO!) (YES)

Maintenance Screen 4-13Port UnloopPressing Enter takes down the specified loop from the currently selected port. Bit ErrorRate Testing(BERT)BERT

Pagina 43 - 4-9

4-14 TERMINAL OPERATIONErrored SecondsThis field displays the number of asynchronous errored seconds that have been detected since the test began or s

Pagina 44 - Maintenance

Configuration Screens 4-15LineParametersThe Line Parameters screen (Figure 4-9) allows reviewing and setting line parameters for the selected el

Pagina 45 - Loopback Diagrams

1GENERALIntroductionThe TxPORT PRISM 3001 (Figure 1-1) is a modular, single port, fractional T1 CSU/DSU. The unit allows connection of high-speed digi

Pagina 46 - Figure 4-8

4-16 TERMINAL OPERATIONNETWORK. Timing is derived from the network recovered clock (most applications use this selection). STATION. Timing is derive

Pagina 47 - 4-13

Configuration Screens 4-17# of ChannelsSets the number of channels to be passed through to the T1 DTE, from 1 through 24.Channel AllocationThis

Pagina 48

4-18 TERMINAL OPERATIONDTE LOS/LOF SecondsA one-second period in which the T1 received signal (on the units DTE side) is interrupted or the amplitude

Pagina 49 - Line Parameters Screen

Configuration Screens 4-19PortParametersThe Port Configuration screen (Figure 4-11) sets the operating parameters for the high-speed port. The u

Pagina 50 - 4-16 TERMINAL OPERATION

4-20 TERMINAL OPERATIONPort RateSelects the required port bit rate in increments of 56 or 64 kbps, depending on the selection in Rate Multiplier. The

Pagina 51 - Alarm Parameters Screen

Utilities Screen 4-21UtilitiesScreen The Utilities screen (Figure 4-13) handles the functions described in the following paragraphs.SetTimeThe c

Pagina 52 - 4-18 TERMINAL OPERATION

4-22 TERMINAL OPERATIONThe unit makes three attempts to connect using the primary number. If all three attempts fail, it makes three attempts to conne

Pagina 53 - Port Parameters Screen

Affidavit for the Connection of Customer Premises Equipment to 1.544 Mbps and/or Subrate Digital ServicesFor work to be performed in the certified ter

Pagina 54 - High-speed Data Port

I attest that the operator(s) maintainer(s) of the digital CPE responsible for the establishment,maintenance and adjustment of the encoded analog cont

Pagina 55 - Utilities

1-2 GENERALThe unit may be controlled through a VT100 terminal or a computer with ANSI terminal emulation software. If used with the EM8000 Element Ma

Pagina 56 - ERMINAL OPERATION

Specifications 1-3EquipmentInterfaceT1 DTE port: optional Line Rate: 1.544 Mbps, ±50 ppm Line Framing: D4 or ESF Line Code: AMI or B8ZS Input S

Pagina 57

1-4 GENERALMechanicalStand-alone: Mounting: desktop, wall, horizontal or vertical rack, and vertical nest mount Dimensions: 1.75" (4.45 cm) wide,

Pagina 58 - (Telco’s Name)

FCC Requirements 1-5This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC

Comentarios a estos manuales